Initial commit: ADSP-219x disassembler, docs, test ROMs, analysis tools

- Standalone Python disassembler for 24-bit ADSP-219x instructions
- Complete instruction set reference (PDFs + extracted text)
- Architecture documentation and getting-started guide
- Test ROM generator with packed (3-byte) and padded (4-byte) formats
- r2pipe-based analysis script for radare2 integration
This commit is contained in:
Siggi
2026-04-12 13:05:38 +00:00
parent b0102ccfda
commit 6af34837d2
28 changed files with 14192 additions and 0 deletions

45
analysis/analyze_rom.py Normal file
View File

@@ -0,0 +1,45 @@
import r2pipe
import json
import sys
# Load local disasm from disassembler dir
sys.path.append("../disassembler")
from adsp219x_disasm import decode_24
def analyze_rom(filename):
"""
Automated ROM analysis using radare2 + Python disassembler.
"""
r2 = r2pipe.open(filename)
r2.cmd("e asm.arch = adsp219x") # Custom arch handled by our script logic
r2.cmd("aa") # Basic analysis (will fail but good practice)
# Iterate over file bytes
file_info = json.loads(r2.cmd("iX"))
size = file_info[0]["size"]
print(f"Analyzing {filename} ({size} bytes)...")
# 3-byte step for ADSP-219x
for offset in range(0, size, 3):
# Read 3 bytes
chunk = r2.cmdj(f"pxj 3 @ {offset}")
if not chunk or len(chunk) < 3: break
opcode = (chunk[0] << 16) | (chunk[1] << 8) | chunk[2]
disasm = decode_24(opcode)
# Set flags, comments, etc., back into r2
r2.cmd(f"CC {disasm} @ {offset}")
print(f"0x{offset:04X}: {disasm}")
# Output comment report
print("\nAnalysis Summary:\n")
print(r2.cmd("CC"))
r2.quit()
if __name__ == "__main__":
if len(sys.argv) < 2:
print("Usage: analyze_rom.py <rom.bin>")
else:
analyze_rom(sys.argv[1])

View File

@@ -0,0 +1,147 @@
import sys
# AMF (ALU/Multiplier Function) codes (5 bits, 0-31)
AMF_ALU = {
0x10: "Y", 0x11: "Y+1", 0x12: "X+Y+C", 0x13: "X+Y",
0x14: "NOT Y", 0x15: "-Y", 0x16: "X-Y+C-1", 0x17: "X-Y",
0x18: "Y-1", 0x19: "Y-X", 0x1a: "Y-X+C-1", 0x1b: "NOT X",
0x1c: "X AND Y", 0x1d: "X OR Y", 0x1e: "X XOR Y", 0x1f: "ABS X"
}
AMF_MAC = {
0x00: "NOP", 0x01: "X * Y (RND)", 0x02: "MR + X * Y (RND)",
0x03: "MR - X * Y (RND)", 0x04: "X * Y (SS)", 0x05: "X * Y (SU)",
0x06: "X * Y (US)", 0x07: "X * Y (UU)", 0x08: "MR + X * Y (SS)",
0x09: "MR + X * Y (SU)", 0x0a: "MR + X * Y (US)", 0x0b: "MR + X * Y (UU)",
0x0c: "MR - X * Y (SS)", 0x0d: "MR - X * Y (SU)", 0x0e: "MR - X * Y (US)",
0x0f: "MR - X * Y (UU)"
}
# Registers (RGP, Address)
REG_MAP = {
(0,0): "AX0", (0,1): "AX1", (0,2): "MX0", (0,3): "MX1",
(0,4): "AY0", (0,5): "AY1", (0,6): "MY0", (0,7): "MY1",
(0,8): "MR2", (0,9): "SR2", (0,10): "AR", (0,11): "SI",
(0,12): "MR1", (0,13): "SR1", (0,14): "MR0", (0,15): "SR0",
(1,0): "I0", (1,1): "I1", (1,2): "I2", (1,3): "I3",
(1,4): "M0", (1,5): "M1", (1,6): "M2", (1,7): "M3",
(1,8): "L0", (1,9): "L1", (1,10): "L2", (1,11): "L3",
(1,12): "IMASK", (1,13): "IRPTL", (1,14): "ICNTL", (1,15): "STACKA",
(2,0): "I4", (2,1): "I5", (2,2): "I6", (2,3): "I7",
(2,4): "M4", (2,5): "M5", (2,6): "M6", (2,7): "M7",
(2,8): "L4", (2,9): "L5", (2,10): "L6", (2,11): "L7",
(2,12): "RSVD", (2,13): "CNTR", (2,14): "LPSTACKA", (2,15): "RSVD",
(3,0): "ASTAT", (3,1): "MSTAT", (3,2): "SSTAT", (3,3): "LPSTACKP",
(3,4): "CCODE", (3,5): "SE", (3,6): "SB", (3,7): "PX",
(3,8): "DMPG1", (3,9): "DMPG2", (3,10): "IOPG", (3,11): "IJPG",
(3,15): "STACKP"
}
# Condition Codes
COND_CODES = {
0x0: "EQ", 0x1: "NE", 0x2: "GT", 0x3: "LE", 0x4: "LT", 0x5: "GE",
0x6: "AV", 0x7: "NOT AV", 0x8: "AC", 0x9: "NOT AC", 0xA: "SWCOND",
0xB: "NOT SWCOND", 0xC: "MV", 0xD: "NOT MV", 0xE: "NOT CE", 0xF: "TRUE"
}
# XOP/YOP Code for ALU/MAC
XOP_ALU = ["AX0", "AX1", "AR", "MR0", "MR1", "MR2", "SR0", "SR1"]
YOP_ALU = ["AY0", "AY1", "AF", "0"] # 11 = 0
XOP_MAC = ["MX0", "MX1", "AR", "MR0", "MR1", "MR2", "SR0", "SR1"]
YOP_MAC = ["MY0", "MY1", "SR1", "0"]
def get_reg_name(rgp, addr):
return REG_MAP.get((rgp, addr), f"REG({rgp},{addr})")
def decode_24(opcode):
"""
Decodes a 24-bit ADSP-219x instruction into its assembly string.
"""
# Type 1: 11xxxxxx (Compute | DregX←DM | DregY←PM)
if (opcode >> 22) == 0b11:
pd = (opcode >> 20) & 0x3
dd = (opcode >> 18) & 0x3
amf = (opcode >> 13) & 0x1F
yop = (opcode >> 11) & 0x3
xop = (opcode >> 8) & 0x7
pmi = (opcode >> 6) & 0x3
pmm = (opcode >> 4) & 0x3
dmi = (opcode >> 2) & 0x3
dmm = opcode & 0x3
# Check for NOP multifunction (All AMF bits zero)
if amf == 0:
comp_str = "NOP"
elif amf >= 0x10:
comp_str = f"{AMF_ALU[amf]}({XOP_ALU[xop]}, {YOP_ALU[yop]})"
else:
comp_str = f"{AMF_MAC[amf]}({XOP_MAC[xop]}, {YOP_MAC[yop]})"
return f"{comp_str}, {XOP_ALU[dd]} = DM(I{dmi} += M{dmm}), {YOP_ALU[pd]} = PM(I{pmi+4} += M{pmm+4})"
# Type 3: Register read/write to immediate 16-bit address
# Type 3 (Ireg/Mreg): 101 D addr16 IREG/MREG
if (opcode >> 21) == 0b101:
d = (opcode >> 20) & 0x1
addr = (opcode >> 4) & 0xFFFF
reg_code = opcode & 0xF
reg_rgp = 1 if reg_code < 8 else 1 # Simple I/M mapping for type 3
# In reality, Type 3 Ireg/Mreg uses a specific table. 0-7 are I0-I7, 8-15 are M0-M7.
reg_name = f"I{reg_code}" if reg_code < 8 else f"M{reg_code-8}"
if d: return f"DM(0x{addr:04X}) = {reg_name}"
else: return f"{reg_name} = DM(0x{addr:04X})"
# Type 6: 0100 Dreg Data16 (Dreg = Data16)
if (opcode >> 20) == 0b0100:
data = (opcode >> 4) & 0xFFFF
dreg = opcode & 0xF
reg_name = get_reg_name(0, dreg)
return f"{reg_name} = 0x{data:04X}"
# Type 10: 000110B addr13 COND (Jump relative)
if (opcode >> 19) == 0b00011:
type_bits = (opcode >> 17) & 0x7
if type_bits == 0b110: # Type 10: 00011 0 delayed(B) ...
b = (opcode >> 16) & 0x1
addr = (opcode >> 4) & 0x1FFF
cond = opcode & 0xF
db = " (DB)" if b else ""
cond_str = f"IF {COND_CODES[cond]} " if cond != 0xF else ""
return f"{cond_str}JUMP 0x{addr:04X}{db}"
elif type_bits == 0b100: # Type 12: Shift | Dreg ...
pass # TODO
# Type 30: 00000000 (NOP)
if (opcode >> 12) == 0:
return "NOP"
return f"UNKNOWN (0x{opcode:06X})"
def main():
if len(sys.argv) < 2:
print("Usage: adsp219x_disasm.py <rom.bin> [3|4 (packed|padded)]")
return
filename = sys.argv[1]
format = int(sys.argv[2]) if len(sys.argv) > 2 else 3 # Default 3-byte packed
with open(filename, "rb") as f:
data = f.read()
step = format
for i in range(0, len(data), step):
chunk = data[i:i+step]
if len(chunk) < 3: break
if format == 3:
# Packed: B0 B1 B2
opcode = (chunk[0] << 16) | (chunk[1] << 8) | chunk[2]
else:
# Padded 32-bit (assume leading zero or big-endian dump): 0x00 B0 B1 B2
# or check your dump!
opcode = (chunk[1] << 16) | (chunk[2] << 8) | chunk[3]
addr = i // format
print(f"0x{addr:04X}: 0x{opcode:06X} {decode_24(opcode)}")
if __name__ == "__main__":
main()

BIN
docs/9x_ALUops.pdf Normal file

Binary file not shown.

BIN
docs/9x_flowops.pdf Normal file

Binary file not shown.

2865
docs/9x_flowops.txt Normal file

File diff suppressed because it is too large Load Diff

BIN
docs/9x_intro.pdf Normal file

Binary file not shown.

361
docs/9x_intro.txt Normal file
View File

@@ -0,0 +1,361 @@
1 INTRODUCTION
Figure 1-0.
Table 1-0.
Listing 1-0.
Purpose
The ADSP-219x DSP Instruction Set Reference provides assembly syntax
information for the ADSP-219x Digital Signal Processor (DSP). The syn-
tax descriptions cover instructions that execute within the DSPs processor
core (processing elements, program sequencer, and data address genera-
tors). For architecture and design information on the DSP, see the
ADSP-219x/2191 DSP Hardware Reference.
Audience
DSP system designers and programmers who are familiar with signal pro-
cessing concepts are the primary audience for this manual. This manual
assumes that the audience has a working knowledge of microcomputer
technology and DSP-related mathematics.
DSP system designers and programmers who are unfamiliar with signal
processing can use this manual, but should supplement this manual with
other texts, describing DSP techniques.
All readers, particularly programmers, should refer to the DSPs develop-
ment tools documentation for software development information. For
additional suggested reading, see “For More Information About Analog
Products” on page 1-6.
ADSP-219x DSP Instruction Set Reference 1-1
Contents Overview
Contents Overview
This reference presents instruction information organized by the type of
the instruction. Instruction types relate to the machine language opcode
for the instruction. On this DSP, the opcodes categorize the instructions
by the portions of the DSP architecture that execute the instructions. The
following chapters cover the different types of instructions:
• “Instruction Set Summary” on page 2-1—This chapter provides a
syntax summary of all instructions and describes the conventions
that are used on the instruction reference pages.
• “ALU Instructions” on page 3-1—These instruction specify opera-
tions that occur in the DSPs ALU.
• “MAC Instructions” on page 4-1—These instructions specify oper-
ations that occur in the DSPs MultiplyAccumulator.
• “Shifter Instructions” on page 5-1—These instructions specify
operations that occur in the DSPs Shifter.
• “Multifunction Instructions” on page 6-1—These instructions
specify parallel, single-cycle operations.
• “Data Move Instructions” on page 7-1—These instructions specify
memory and register access operations.
• “Program Flow Instructions” on page 8-1—These instructions spec-
ify program sequencer operations.
• “Instruction Opcodes” on page 9-1—This chapter lists the instruc-
tion encoding fields for all instructions.
Each of the DSPs instructions is specified in this text. The reference page
for an instruction shows the syntax of the instruction, describes its func-
tion, gives one or two assembly-language examples, and identifies fields of
its opcode. The instructions are referred to by type, ranging from 1 to 37.
1-2 ADSP-219x DSP Instruction Set Reference
Introduction
These types correspond to the opcodes that ADSP-219x DSPs recognize,
but are for reference only and have no bearing on programming.
Some instructions have more than one syntactical form; for example,
instruction “Type 9: Compute” on page 9-27 has many distinct forms.
Many instructions can be conditional. These instructions are prefaced by
IF COND; for example:
If COND compute;
In a conditional instruction, the execution of the entire instruction is
based on the specified condition.
Development Tools
The ADSP-219x is supported by VisualDSP®, an easy-to-use project
management environment, comprised of an Integrated Development
Environment (IDE) and Debugger. VisualDSP lets you manage projects
from start to finish from within a single, integrated interface. Because the
project development and debug environments are integrated, you can
move easily between editing, building, and debugging activities.
Flexible Project Management. The IDE provides flexible project manage-
ment for the development of DSP applications. The IDE includes access
to all the activities necessary to create and debug DSP projects. You can
create or modify source files or view listing or map files with the IDE Edi-
tor. This powerful Editor is part of the IDE and includes multiple
language syntax highlighting, OLE drag and drop, bookmarks, and stan-
dard editing operations such as undo/redo, find/replace, copy/paste/cut,
and goto.
Also, the IDE includes access to the C Compiler, C Runtime Library,
Assembler, Linker, Loader, Simulator, and Splitter. You specify options
for these Tools through Property Page dialogs. Property Page dialogs are
easy to use, and make configuring, changing, and managing your projects
ADSP-219x DSP Instruction Set Reference 1-3
Development Tools
simple. These options control how the tools process inputs and generate
outputs, and have a one-to-one correspondence to the tools command
line switches. You can define these options once, or modify them to meet
changing development needs. You can also access the Tools from the oper-
ating system command line if you choose.
Greatly Reduced Debugging Time. The Debugger has an easy-to-use,
common interface for all processor simulators and emulators available
through Analog Devices and third parties or custom developments. The
Debugger has many features that greatly reduce debugging time. You can
view C source interspersed with the resulting Assembly code. You can pro-
file execution of a range of instructions in a program; set simulated watch
points on hardware and software registers, program and data memory; and
trace instruction execution and memory accesses. These features enable
you to correct coding errors, identify bottlenecks, and examine DSP per-
formance. You can use the custom register option to select any
combination of registers to view in a single window. The Debugger can
also generate inputs, outputs, and interrupts so you can simulate real
world application conditions.
Software Development Tools. Software Development Tools, which sup-
port the ADSP-219x Family, allow you to develop applications that take
full advantage of the DSP architecture, including shared memory and
memory overlays. Software Development Tools include C Compiler, C
Runtime Library, DSP and Math Libraries, Assembler, Linker, Loader,
Simulator, and Splitter.
C Compiler & Assembler. The C Compiler generates efficient code that is
optimized for both code density and execution time. The C Compiler
allows you to include Assembly language statements inline. Because of
this, you can program in C and still use Assembly for time-critical loops.
You can also use pretested Math, DSP, and C Runtime Library routines to
help shorten your time to market. The ADSP-219x Family Assembly lan-
guage is based on an algebraic syntax that is easy to learn, program, and
1-4 ADSP-219x DSP Instruction Set Reference
Introduction
debug. The add instruction, for example, is written in the same manner as
the actual equation (for example, AR = AX0 + AY0;).
Linker & Loader. The Linker provides flexible system definition through
Linker Description Files (.LDF). In a single LDF, you can define different
types of executables for a single or multiprocessor system. The Linker
resolves symbols over multiple executables, maximizes memory use, and
easily shares common code among multiple processors. The Loader sup-
ports creation of host (8- or 16-bit) port, SPI port, UART port, and
PROM boot images. Along with the Linker, the Loader allows a variety of
system configurations with smaller code and faster boot time.
Simulator. The Simulator is a cycle-accurate, instruction-level simulator
— allowing you to simulate your application in real time.
3rd-Party Extensible. The VisualDSP environment enables third-party
companies to add value using Analog Devices published set of Applica-
tion Programming Interfaces (API). Third party products—runtime
operating systems, emulators, high-level language compilers, multiproces-
sor hardware —can interface seamlessly with VisualDSP thereby
simplifying the tools integration task. VisualDSP follows the COM API
format. Two API tools, Target Wizard and API Tester, are also available
for use with the API set. These tools help speed the time-to-market for
vendor products. Target Wizard builds the programming shell based on
API features the vendor requires. The API tester exercises the individual
features independently of VisualDSP. Third parties can use a subset of
these APIs that meets their application needs. The interfaces are fully sup-
ported and backward compatible.
Further details and ordering information are available in the VisualDSP
Development Tools data sheet. This data sheet can be requested from any
Analog Devices sales office or distributor.
ADSP-219x DSP Instruction Set Reference 1-5
For More Information About Analog Products
For More Information About Analog
Products
Analog Devices is online on the internet at http://www.analog.com. Our
Web pages provide information on the company and products, including
access to technical information and documentation, product overviews,
and product announcements.
You may also obtain additional information about Analog Devices and its
products in any of the following ways:
• Visit our World Wide Web site at www.analog.com
• FAX questions or requests for information to 1(781)461-3010.
• Access the Computer Products Division File Transfer Protocol
(FTP) site at ftp ftp.analog.com or ftp 137.71.23.21 or
ftp://ftp.analog.com.
For Technical or Customer Support
You can reach our Customer Support group in the following ways:
• E-mail questions to dsp.support@analog.com or
dsp.europe@analog.com (European customer support)
• Telex questions to 924491, TWX:710/394-6577
• Cable questions to ANALOG NORWOODMASS
• Contact your local ADI sales office or an authorized ADI distributor
1-6 ADSP-219x DSP Instruction Set Reference
Introduction
• Send questions by mail to:
Analog Devices, Inc.
DSP Division
One Technology Way
P.O. Box 9106
Norwood, MA 02062-9106
USA
Whats New in This Manual
This is the preliminary edition of the ADSP-219x DSP Instruction Set
Reference. Summaries of changes between editions will start with the next
edition.
Related Documents
For more information about Analog Devices DSPs and development
products, see the following documents:
• ADSP-2191 DSP Microcomputer Data Sheet
• ADSP-219x/2191 DSP Hardware Reference
• Getting Started Guide for VisualDSP & ADSP-219x Family DSPs
• VisualDSP User's Guide for ADSP-219x Family DSPs
• C Compiler & Library Manual for ADSP-219x Family DSPs
• Assembler Manual for ADSP-219x Family DSPs
• Linker & Utilities Manual for ADSP-219x Family DSPs
All the manuals are included in the software distribution CD-ROM. To
access these manuals, use the Help Topics command in the VisualDSP
environments Help menu and select the Online Manuals book. From this
ADSP-219x DSP Instruction Set Reference 1-7
Conventions
Help topic, you can open any of the manuals, which are in Adobe Acrobat
PDF format.
Conventions
The following are conventions that apply to all chapters. Note that addi-
tional conventions, which apply only to specific chapters, appear
throughout this document.
Table 1-1. Instruction set notation
Notation Meaning
UPPERCASE Explicit syntax—assembler keyword. (The assembler is case-
insensitive.)
; A semicolon terminates an instruction line.
, A comma separates multiple, parallel instructions in the same
instruction line.
// single line comment // or /* */ indicate comments or remarks that explain program code,
/* multi line comment */ but that the assembler ignores. For more details, see the Assembler
Manual for ADSP-219x Family DSPs.
| option1 | You must choose one of the items enclosed within two vertical bars.
| option2 |
[ (DB) ] Brackets enclose an optional instruction component. The options
syntax includes everything within the brackets, as shown. In this
case, (DB) is the delayed branch option.
<imm#> Denotes an immediate value (data or address) of # bits.
<data#>
COND Denotes a status condition.
1-8 ADSP-219x DSP Instruction Set Reference
Introduction
Table 1-1. Instruction set notation (Contd)
Notation Meaning
TERM Denotes a loop termination condition. For details, see “Type 11: Do
··· Until” on page 9-34.
Dreg Denotes an unrestricted (Group 0) data register used as either an x
or y-input operand. For details, see “Core Registers” on page 7-2.
XOP Denotes a restricted data register used for the x-input operand in a
compute instruction. For details, see “Input Registers” on page 3-2.
YOP Denotes a restricted data register used for the y-input operand in a
compute operation. For details, see “Input Registers” on page 3-2.
Ireg DAG address register. Denotes an index register (I0I7).
Mreg DAG address register. Denotes a modify register (M0M7).
Lreg DAG address register. Denotes a length register (L0L7).
Breg DAG address register. Denotes a base register (B0B7).
(Ireg + Mreg) Indirect addressing mode. Denotes premodify addressing with no
update. Same as (Mreg, Ireg) syntax.
(Ireg += Mreg) Indirect addressing mode. Denotes postmodify addressing with
update. Same as (Ireg, Mreg) syntax.
0x Denotes number in hexidecimal format (0xFFFF).
h# Denotes number in hexidecimal format (h#FFFF).
b# Denotes number in binary format (b#0001000100010001).
ADSP-219x DSP Instruction Set Reference 1-9
Conventions
1-10 ADSP-219x DSP Instruction Set Reference

BIN
docs/9x_is_IX.pdf Normal file

Binary file not shown.

BIN
docs/9x_is_TC.pdf Normal file

Binary file not shown.

BIN
docs/9x_iset.pdf Normal file

Binary file not shown.

1021
docs/9x_iset.txt Normal file

File diff suppressed because it is too large Load Diff

BIN
docs/9x_mltops.pdf Normal file

Binary file not shown.

926
docs/9x_mltops.txt Normal file
View File

@@ -0,0 +1,926 @@
4 MAC INSTRUCTIONS
Figure 4-0.
Table 4-0.
Listing 4-0.
The instruction set provides MAC instructions for performing high-speed
multiplication and multiply with cumulative add/subtract operations.
MAC instructions include:
• “Multiply” on page 4-8
• “Multiply with Cumulative Add” on page 4-11
• “Multiply with Cumulative Subtract” on page 4-14
• “MAC Clear” on page 4-17
• “MAC Round/Transfer” on page 4-19
• “MAC Saturate” on page 4-21
• “Generate MAC Status Only: NONE” on page 4-24
This chapter describes the individual MAC instructions and the following
related topics:
• “MAC Input Registers” on page 4-2
• “MAC Output Registers” on page 4-2
• “Data Format Options” on page 4-3
• “Status Flags” on page 4-7
For details on condition codes and data input and output registers, see
“Condition Codes” on page 9-11 and “Core Register Codes” on page
9-13.
ADSP-219x Instruction Set Reference 4-1
MAC Instructions
MAC Input Registers
All unconditional, single-function multiply and multiply with accumula-
tive add or subtract instructions can use any DREG data register for the x
and y input operands (for details, see “Core Register Codes” on page
9-13). So, the program can use, for example, the ALU registers for the
multiplication or shifter operations, without issuing a separate data move
instruction. This capability simplifies register allocation in algorithm cod-
ing. For example, using the DSPs dual accumulator:
SR = SR + MX0 * MY0 (SS);
But in multifunction operations, you can use only certain registers for the
x-input operand (AR, MX0, MX1, MR0, MR1, MR2, SR0, SR1) and the y-input
operand ( MY0, MY1, SR1, 0).
All conditional MAC instructions must use the restricted xop and yop data
registers for the x and y input operands, or an xop register for the x-input
and 0 for the y-input.
MAC Output Registers
All MAC instructions can use the multiplier MR output registers or the
shifter SR output registers to receive the result of a multiplier operation.
Availability of the shifter SR output registers for multiplier operations pro-
vides dual accumulator functionality.
When MR is the result register, results are directly available from MR0, MR1,
or MR2 as the x-input operand into the very next multiplier operation.
MR = MR + AX0 * AX0 (SS);
When SR is the result register, the 16-bit value in SR1 (bits 31:16 of the
40-bit result) is directly available as the y-input operand into the very next
multiplier operation. This functionality is most useful when shifting the
4-2 ADSP-219x Instruction Set Reference
Data Format Options
results of a multiply/accumulate operation since it decreases the number
of required data moves.
SR = SR + AX0 * AY0 (SS);
SR = SR + SR1 * AY0 (SS);
Data Format Options
Multiplier operations require the instruction to specify the data format of
the input operands (either signed or unsigned) or specify that the multi-
plier rounds (RND) the product of two signed operands.
All data format options, except the round option ( RND), which affects the
product stored in the result register, specify the format of both input oper-
ands in x/y order. The data format options are:
• (RND) Round value in result register.
When overflow occurs, rounds the product to the most significant
twenty-four bits—SR2/SR1 or MR2/MR1 represent the rounded 24-bit
result. Otherwise, rounds bits 31:16 to sixteen bits—MR1 or SR1 con-
tain the rounded 16-bit result.
With (RND) selected, the multiplier considers both input operands
signed (twos complement). If the DSP is in fractional mode
(MSTAT:M_MODE = 0), the multiplier rounds the result after adjusting
for fractional data format. For details, see “Numeric Format Modes”
on page 4-6.
The DSP provides two rounding modes, biased and unbiased, to
support a variety of application algorithms. For details, see “Round-
ing Modes” on page 4-4.
ADSP-219x Instruction Set Reference 4-3
MAC Instructions
• (SS) Both input operands are signed numbers. Signed numbers
are in twos complement format.
You use this option to multiply two signed single-precision numbers
or to multiply the upper portions of two signed multiprecision
numbers.
• (SU) X-input operand is signed; y-input operand is unsigned.
You use this option to multiply a signed single-precision number by
an unsigned single-precision number.
• (US) X-input operand is unsigned; y-input operand is signed.
You use this option to multiply an unsigned single-precision num-
ber by a signed single-precision number.
• (UU) Both input operands are unsigned numbers. Unsigned num-
bers are in ones complement format.
You use this option to multiply two unsigned single-precision num-
bers or to multiply the lower portions of two signed multiprecision
numbers.
Rounding Modes
Rounding operates on the boundary between bits 15 and 16 of the 40-bit
adder result. The multiplier directs the rounded output to either the MR
or the SR result registers.
The ADSP-219x provides two modes for rounding. The rounding algo-
rithm is the same for both modes, but the final results can differ when the
product equals the midway value (MR0 = 0x8000).
In both methods, the multiplier adds 1 to value of bit 15 in the adder
chain. But when MR0 = 0x8000, the multiplier forces bit 16 in the result
output to 0. Although applied on every rounding operation, the result of
this algorithm is evident only when MR0 = 0x8000 in the adder chain.
4-4 ADSP-219x Instruction Set Reference
Data Format Options
The rounding mode determines the final result. The BIASRND bit in the
ICNTL register selects the mode. BIASRND = 0 selects unbiased rounding,
and BIASRND = 1 selects biased rounding.
• Unbiased rounding Default mode. Rounds up only when
MR1/SR1 set to an odd value; otherwise,
rounds down. Yields a zero large-sample bias.
• Biased rounding Always rounds up when MR0/SR0 is set to
0x8000.
Table 4-1 shows the results of rounding for both modes.
Table 4-1. MR result values
MR Value before RND Biased RND Result Unbiased RND Result
00-0000-8000 00-0001-0000 00-0000-0000
00-0001-8000 00-0002-0000 00-0002-0000
00-0000-8001 00-0001-0001 00-0001-0001
00-0001-8001 00-0002-0001 00-0002-0001
00-0000-7FFF 00-0000-FFFF 00-0000-FFFF
00-0001-7FFF 00-0001-FFFF 00-0001- FFFF
Unbiased rounding, preferred for most algorithms, yields a zero large-sam-
ple bias, assuming uniformly distributed values. Biased rounding supports
efficient implementation of bit-specified algorithms, such as GSM speech
compression routines.
ADSP-219x Instruction Set Reference 4-5
MAC Instructions
Numeric Format Modes
The multiplier can operate on integers or fractions. The M_MODE bit in the
MSTAT register selects the mode. M_MODE = 0 selects fractional mode, and
M_MODE = 1 selects integer mode.
The mode determines whether the multiplier shifts the product before
adding or subtracting it from the result register.
• Integer mode 16.0 integer format
The LSB of the 32-bit product is aligned with the LSB of MR0/SR0.
In multiply and accumulate operations, the multiplier sign-extends
the 32-bit product (8 bits) then adds or subtracts that value from the
result register to form the new 40-bit result.
The multiplier sets the MV/SV overflow bit when the result falls out-
side the range of 1 to +1231.
• Fractional mode 1.15 fraction format
Fractions range from 1 to +1215. The MSB of the product is
aligned with the MSB of MR1/SR1. MR1-0/SR1-0 hold a 32-bit frac-
tion (1.31 format) in the range of 1 to +1231, while MR2/SR2 con-
tains the eight sign-extended bits. In total, the MR/SR registers
contains a fraction in 9.31 format.
In multiply and accumulate operations, the multiplier adjusts the
format of the 32-bit product before adding or subtracting it from
the result register. To do so, the multiplier sign-extends the product
(7 bits), shifts it one bit to the left, and then adds or subtracts that
value from the result register to form the new 40-bit result.
The multiplier sets the MV/SV overflow bit when the result falls out-
side the range of 1 to +1231.
4-6 ADSP-219x Instruction Set Reference
Status Flags
Status Flags
Two status flags in the ASTAT register record the status of multiplier opera-
tions. MV = 1 records an overflow or underflow state when MR is the
specified result register, and SV = 1 records an overflow or underflow state
when SR is the specified result register.
ADSP-219x Instruction Set Reference 4-7
MAC Instructions
Multiply
MR = DREG1 * DREG2 ( RND ) ;
SR SS
SU
US
UU
[IF COND] MR = XOP * YOP ( RND ) ;
SR XOP SS
SU
US
UU
FUNCTION
Multiplies the input operands and stores the result in the specified result
register. Optionally, inputs may be signed or unsigned, and output may be
rounded. For more information on input and output options, see “Data
Format Options” on page 4-3.
If execution is based on a condition, the multiplier performs the multipli-
cation only if the condition evaluates true, and it performs a NOP operation
if the condition evaluates false. Omitting the condition forces uncondi-
tional execution of the instruction.
4-8 ADSP-219x Instruction Set Reference
Multiply
INPUT
For the unconditional form of this instruction, you can use any of these
data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
For the conditional form of this instruction, the input operands are
restricted. Valid XOP and YOP registers are:
Xops Yops
AR, MX0, MX1, MR0, MR1, MR2, SR0, SR1 MY0, MY1, SR1, 0
OUTPUT
MR Multiplier result register. Results are directly available for x input
only in the next conditional ALU, MAC, or shifter operation or as
either x or y input in the next unconditional ALU, MAC, or shifter
operation.
SR Multiplier feedback register. Results are directly available for either
x ( SR0 and SR1) or y (SR1 only) input in the next conditional ALU,
MAC, or shifter operation or as either x or y input in the next
unconditional ALU, MAC, or shifter operation.
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
MV (if MR used), SV (if SR used) AZ, AN, AV, AC, AS, AQ, SS
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
ADSP-219x Instruction Set Reference 4-9
MAC Instructions
DETAILS
This instruction provides a squaring operation (XOP*XOP and DREG1*DREG1)
that performs single-cycle X2 and ΣX2 functions. In squaring operations,
you must use the same register for both x-input operands.
You cannot use DREG form of the multiply instruction in multifunction
instructions.
EXAMPLES
MR = AY0 * SI (RND); /* mult DREGs, round result */
SR = AX0 * MX1 (SS); /* mult DREGs, signed inputs */
IF MV MR = MX0 * MY0 (SU); /* mult signed X, unsigned Y */
CCODE = 0x09; NOP; /* set CCODE for SV condition */
IF SWCOND SR = MR0 * SR1 (UU); /* mult unsigned X and Y */
SEE ALSO
• “Type 9: Compute” on page 9-27
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
4-10 ADSP-219x Instruction Set Reference
Multiply with Cumulative Add
Multiply with Cumulative Add
MR = MR + DREG1 * DREG2 ( RND ) ;
SR = SR SS
SU
US
UU
[IF COND] MR = MR + XOP * YOP ( RND ) ;
SR = SR YOP XOP SS
SU
US
UU
FUNCTION
Multiplies the input operands, adds the product to the current contents of
the MR or SR register, and then stores the sum in the corresponding result
register. Optionally, inputs may be signed or unsigned, and output may be
rounded. For more information on input and output options, see “Data
Format Options” on page 4-3.
If execution is based on a condition, the multiplier performs the operation
only if the condition evaluates true, and it performs a NOP operation if the
condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
ADSP-219x Instruction Set Reference 4-11
MAC Instructions
INPUT
For the unconditional form of this instruction, you can use any of these
data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
For the conditional form of this instruction, the input operands are
restricted. Valid XOP and YOP registers are:
Xops Yops
AR, MX0, MX1, MR0, MR1, MR2, SR0, SR1 MY0, MY1, SR1, 0
OUTPUT
MR Multiplier result register. Results are directly available for x input
only in the next conditional ALU, MAC, or shifter operation or as
either x or y input in the next unconditional ALU, MAC, or shifter
operation.
SR Multiplier feedback register. Results are directly available for either
x ( SR0 and SR1) or y (SR1 only) input in the next conditional ALU,
MAC, or shifter operation or as either x or y input in the next
unconditional ALU, MAC, or shifter operation.
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
MV (if MR used), SV (if SR used) AZ, AN, AV, AC, AS, AQ, SS
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
4-12 ADSP-219x Instruction Set Reference
Multiply with Cumulative Add
DETAILS
This instruction provides a squaring operation (xop*xop and DREG*DREG)
that performs single-cycle X2 and ΣX2 functions. In squaring operations,
you must use the same register for both x-input operands.
You cannot use unconditional (Dreg) form of the multiply instruction in
multifunction instructions.
EXAMPLES
MR = MR + AX0 * SI (RND); /* mult DREGs, rnd output, sum */
SR = SR + AX1 * MX0 (SS); /* mult DREGs, sign input, sum */
IF MV MR = MR + MR0 * MY0 (SU);
/* mult X/Yops, un/sign in, sum */
IF MV MR = MR + MR2 * MX1 (UU);
/* mult X/Yops, unsign in, sum */
CCODE = 0x09; NOP; /* set CCODE for SV condition */
IF SWCOND SR=SR+SR0*MY0 (US);
/* mult X/Yops, un/sign in, sum */
SEE ALSO
• “Type 9: Compute” on page 9-27
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
ADSP-219x Instruction Set Reference 4-13
MAC Instructions
Multiply with Cumulative Subtract
MR = MR DREG1 * DREG2 ( RND ) ;
SR = SR SS
SU
US
UU
[IF COND] MR = MR XOP * YOP ( RND ) ;
SR = SR YOP XOP SS
SU
US
UU
FUNCTION
Multiplies the input operands, subtracts the product from the current
contents of the MR or SR register, and then stores the result in the corre-
sponding destination register. Optionally, inputs may be signed or
unsigned, and output may be rounded. For more information on input
and output options, see “Data Format Options” on page 4-3.
If execution is based on a condition, the multiplier performs the operation
only if the condition evaluates true, and it performs a NOP operation if the
condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
4-14 ADSP-219x Instruction Set Reference
Multiply with Cumulative Subtract
INPUT
For the unconditional form of this instruction, you can use any of these
data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
For the conditional form of this instruction, the input operands are
restricted. Valid XOP and YOP registers are:
Xops Yops
AR, MX0, MX1, MR0, MR1, MR2, SR0, SR1 MY0, MY1, SR1, 0
OUTPUT
MR Multiplier result register. Results are directly available for x input
only in the next conditional ALU, MAC, or shifter operation or as
either x or y input in the next unconditional ALU, MAC, or shifter
operation.
SR Multiplier feedback register. Results are directly available for either
x ( SR0 and SR1) or y (SR1 only) input in the next conditional ALU,
MAC, or shifter operation or as either x or y input in the next
unconditional ALU, MAC, or shifter operation.
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
MV (if MR used), SV (if SR used) AZ, AN, AV, AC, AS, AQ, SS
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
ADSP-219x Instruction Set Reference 4-15
MAC Instructions
DETAILS
This instruction provides a squaring operation (xop*xop and DREG*DREG)
that performs single-cycle X2 and ΣX2 functions. In squaring operations,
you must use the same register for both x input operands.
You cannot use unconditional (Dreg) form of the multiply instruction in
multifunction instructions.
EXAMPLES
MR = MR - AX0 * SI (RND); /* mult DREGs, rnd output, sub */
SR = SR - AX1 * MX0 (SS); /* mult DREGs, sign input, sub */
IF MV MR = MR - MR0 * MY0 (SU);
/* mult X/Yops, un/sign in, sub */
IF MV MR = MR - MR2 * MX1 (UU);
/* mult X/Yops, unsign in, sub */
CCODE = 0x09; NOP; /* set CCODE for SV condition */
IF SWCOND SR=SR-SR0*MY0 (US);
/* mult X/Yops, un/sign in, sub */
SEE ALSO
• “Type 9: Compute” on page 9-27
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
4-16 ADSP-219x Instruction Set Reference
MAC Clear
MAC Clear
[IF COND] MR = 0 ;
SR
FUNCTION
Sets the specified register to 0.
If execution is based on a condition, the multiplier performs the operation
only if the condition evaluates true, and it performs a NOP operation if
the condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
INPUT
This instruction is a special case of xop * yop with the y-input operand set
to 0.
OUTPUT
MR Multiplier result register. Results are directly available for x input
only in the next conditional ALU, MAC, or shifter operation or as
either x or y input in the next unconditional ALU, MAC, or shifter
operation.
SR Multiplier feedback register. Results are directly available for either
x ( SR0 and SR1) or y (SR1 only) input in the next conditional ALU,
MAC, or shifter operation or as either x or y input in the next
unconditional ALU, MAC, or shifter operation.
ADSP-219x Instruction Set Reference 4-17
MAC Instructions
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
MV (cleared if MR used), SV (cleared if SR used) AZ, AN, AV, AC, AS, AQ, SS
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
See description in “function” on page 4-17.
EXAMPLES
MR = 0; /* clears MR */
SR = 0; /* clears SR */
SEE ALSO
• “Type 9: Compute” on page 9-27
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
4-18 ADSP-219x Instruction Set Reference
MAC Round/Transfer
MAC Round/Transfer
[IF COND] MR = MR (RND) ;
[IF COND] SR = SR (RND) ;
FUNCTION
Performs a multiply with cumulative add operation in which the y-input
operand is 0 and the zero-product is added to the specified result register.
Rounding (RND) directs the multiplier to round the entire 40-bit value
stored in the result register, MR or SR.
If execution is based on a condition, the multiplier performs the operation
only if the condition evaluates true, and it performs a NOP operation if the
condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
INPUT
This instruction is a special case of MR|SR + xop * yop with the y-input
operand set to 0.
OUTPUT
MR Multiplier result register. Results are directly available for x input
only in the next conditional ALU, MAC, or shifter operation or as
either x or y input in the next unconditional ALU, MAC, or shifter
operation.
SR Multiplier feedback register. Results are directly available for either
x ( SR0 and SR1) or y (SR1 only) input in the next conditional ALU,
MAC, or shifter operation or as either x or y input in the next
unconditional ALU, MAC, or shifter operation.
ADSP-219x Instruction Set Reference 4-19
MAC Instructions
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
MV (if MR used), SV (if SR used) AZ, AN, AV, AC, AS, AQ, SS
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
The BIASRND bit in the ICNTL register determines the rounding mode.
Refer to the section “Rounding Modes” on page 4-4 for more informa-
tion. For a complete description of the MAC Round/ Transfer
instruction, see the section “function” on page 4-19.
EXAMPLES
MR = MR (RND); /* round MR */
IF EQ SR = SR (RND); /* round SR */
SEE ALSO
• “Type 9: Compute” on page 9-27
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
4-20 ADSP-219x Instruction Set Reference
MAC Saturate
MAC Saturate
SAT MR ;
SAT SR ;
FUNCTION
Tests the MV (MAC overflow) or SV (shifter overflow) bit in the ASTAT reg-
ister. If set ( 1), the multiplier saturates the low-order (31:0) bits of the
40-bit MR or SR register; otherwise, the multiplier performs a NOP
operation.
INPUT
None.
OUTPUT
MR Multiplier result register. Results are directly available for x input
only in the next conditional ALU, MAC, or shifter operation or as
either x or y input in the next unconditional ALU, MAC, or shifter
operation.
SR Multiplier feedback register. Results are directly available for either
x ( SR0 and SR1) or y (SR1 only) input in the next conditional ALU,
MAC, or shifter operation or as either x or y input in the next
unconditional ALU, MAC, or shifter operation.
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
AZ, AN, AV, AC, AS, AQ, SS, MV, SV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
ADSP-219x Instruction Set Reference 4-21
MAC Instructions
DETAILS
The MAC saturation instruction provides control over a multiplication
result that has overflowed or underflowed. It saturates the value in the
specified register only for the cycle in which it executes. It does not enable
a mode that continuously saturates results until disabled, like the ALU.
Used at the end of a series of multiply and accumulate operations, the sat-
uration instruction prevents the accumulator from overflowing.
For every operation it performs, the multiplier generates an overflow sta-
tus signal MV (SV when SR is the specified result register), which is recorded
in the ASTAT status register. MV = 1 when the accumulator result, inter-
preted as a signed (twos complement) number, crosses the 32-bit
boundary, spilling over from MR1 into MR2. That is, the multiplier sets
MV = 1 when the upper nine bits in MR are anything other than all 0s or all
1s. Otherwise, it sets MV = 0.
The operation invoked by the saturation instruction depends on the over-
flow status bit MV (or SV) and the MSB of MR2, which appear in Table 4-2.
If MV/SV = 0, no saturation occurs. When MV/SV = 1, the multiplier exam-
ines the MSB of MR2 to determine whether the result has overflowed or
underflowed. If the MSB = 0, the result has overflowed, and the multiplier
saturates the MR register, setting it to the maximum positive value. If the
MSB = 1, the result has underflowed, and the multiplier saturates the MR
register, setting it to the maximum negative value.
Table 4-2. Saturation Status Bits & Result Registers
MV/SV MSB of MR2/SR2 MR/SR Results
0 0 No change.
0 1 No change.
1 0 00000000 0111111111111111 1111111111111111
1 1 11111111 1000000000000000 0000000000000000
4-22 ADSP-219x Instruction Set Reference
MAC Saturate
Do not permit the result to overflow beyond the MSB of MR2. Otherwise,
the true sign bit of the result is irretrievably lost, and saturation may not
produce a correct result. To reach this state, however, takes more than 255
overflows (MV type).
EXAMPLES
SAT MR; /* saturate MR */
SAT SR; /* saturate SR */
SEE ALSO
• “Type 9: Compute” on page 9-27
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
ADSP-219x Instruction Set Reference 4-23
MAC Instructions
Generate MAC Status Only: NONE
[NONE =] <MAC Operation> ;
FUNCTION
Performs the indicated unconditional MAC operation but does not load
the results into the MR or SR result registers. Generates MAC status flags
only. You can use this instruction to set MAC status without disturbing
the contents of the MR and SR result registers.
INPUT
XOP Limits the registers for the x input operand. Valid XOP registers are:
Xops
AR, MX0, MX1, MR0, MR1, MR2, SR0, SR1
YOP Limits the registers for the x input operand. Valid YOP registers are:
Yops
MY0, MY1, SR1, 0
OUTPUT
None. Generates MAC status flags only.
4-24 ADSP-219x Instruction Set Reference
Generate MAC Status Only: NONE
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
MV AZ, AN, AV, AC, AS, AQ, SS, SV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
You can use any unconditional MAC operation to generate MAC status
flags.
EXAMPLES
MX0 * MY0; /* generate status from mult */
SEE ALSO
• “Type 8: Compute | Dreg1 «··· Dreg2” on page 9-26.
ADSP-219x Instruction Set Reference 4-25
MAC Instructions
4-26 ADSP-219x Instruction Set Reference

BIN
docs/9x_moveops.pdf Normal file

Binary file not shown.

2598
docs/9x_moveops.txt Normal file

File diff suppressed because it is too large Load Diff

BIN
docs/9x_multiops.pdf Normal file

Binary file not shown.

791
docs/9x_multiops.txt Normal file
View File

@@ -0,0 +1,791 @@
6 MULTIFUNCTION
INSTRUCTIONS
Figure 6-0.
Table 6-0.
Listing 6-0.
The instruction set provides multifunction instructions—multiple
instructions within a single instruction cycle. Multifunction instructions
can perform (in a single cycle) computations in parallel with data move
operations. Multifunction instructions are combinations of single instruc-
tions delimited with commas and ended with a semicolon, as in:
AR = AX0 - AY0, AX0 = MR1; /* ALU sub and reg.-to-reg. move */
These operations are the basis for all high-performance DSP functions and
take advantage of the DSPs inherent parallelism. Multifunction opera-
tions include:
• “Compute with Dual Memory Read” on page 6-3
• “Dual Memory Read” on page 6-7
• “Compute with Memory Read” on page 6-10
• “Compute with Memory Write” on page 6-14
• “Compute with Register to Register Move” on page 6-18
This chapter describes each of the multifunction instructions and the
order of execution of multifunction operations.
Multifunction instructions combine compute operations with data move
operations. The multifunction combinations have no status flags specifi-
cally associated with them, but the DSP does update the status flags for
the computations that appear within multifunction instructions. For
details, see “Arithmetic Status (ASTAT) Register” on page 2-5.
ADSP-219x Instruction Set Reference 6-1
Multifunction Instructions
Order of Execution of Multifunction Operations
The DSP reads registers and memory at the beginning of the processor
pipeline and writes them at the end of it. Normal instruction syntax, read
from left to right, implies this functional ordering. For example:
a. MR = MR + MX0 * MY0(UU), MX0 = DM(I0 += M0), MY0 = PM(I4 += M4);
b. DM(I0 += M0) = AR, AR = AX0 + AY0;
c. AR = AX0 - AY0, AX0 = MR1;
This means that, for memory reads, the DSP executes the computation
first, using the current value of the input data registers, and then transfers
new data from memory or from another data register, overwriting the con-
tents of the data registers (a and c). For memory writes, the DSP transfers
the current value from the data register to memory first, and then over-
writes the data register with the result of the computation (b).
Even if you alter the order of the operations in your code, execution
occurs in the correct order; the assembler issues a warning (if enabled), but
results are correct at the opcode level. For example:
MX0 = DM(I0 += M0), MY0 = PM(I4 += M4), MR = MR + MX0 * MY0(UU);
The altered order of operations appears to reverse the order in which the
DSP executes the operations, but the DSP always executes instructions
using read-first/write-last logic.
The DSPs read-first/write-last logic enables you to use the same data reg-
ister in more than one multifunction operation. The same data register
can serve as an input operand into the computation and as the destination
or source register for a data move operation. However, except for the com-
pute with memory write instruction, the same register cannot serve as
destination for more than one multifunction operation. Doing so gener-
ates unpredictable and erroneous results.
6-2 ADSP-219x Instruction Set Reference
Compute with Dual Memory Read
Compute with Dual Memory Read
<ALU> , AX0 = DM( I0 += M0 ), AY0 = PM( I4 += M4 );
<MAC> AX1 I1 M1 AY1 I5 M5
MX0 I2 M2 MY0 I6 M6
MX1 I3 M3 MY1 I7 M7
FUNCTION
Combines an ALU or MAC operation with a read from memory over the
16-bit DM data bus and another read from memory over the 24-bit PM
data bus. The restricted register forms—using XOP and YOP registers, not the
DREG register file—of all ALU or MAC instructions are supported, except
for the MAC saturate instruction and the divide primitives DIVS and DIVQ.
Also, the multifunction ALU and MAC instructions may not use condi-
tional (IF) options.
The compute operation executes first, using the current contents of the
data registers as input operands. Then the memory read operations exe-
cute, overwriting the contents of the destination data registers with new
data from memory.
The destination of both memory read operations is an ALU or MAC data
register. The DM bus read loads an ALU or MAC XOP register, and the
PM bus read loads an ALU or MAC YOP register. The memory data is
always right-justified in the destination data register.
INPUT
The input operands for the compute operation are specific to the particu-
lar operation. For details, see the compute instructions individual
description.
• For MAC operations, see “MAC Instructions” on page 4-1.
• For ALU operations, see “ALU Instructions” on page 3-1.
ADSP-219x Instruction Set Reference 6-3
Multifunction Instructions
Both data move operations use two DAG registers, index (Ireg) and mod-
ify (Mreg), to generate memory addresses—DAG1 registers for the DM bus
access, and DAG2 registers for the PM bus access. For details on DAG reg-
isters and data addressing, see “Data Move Instructions” on page 7-1.
• DM/DAG1 I0, I1, I2, or I3 (index registers)
M0, M1, M2, or M3 (modify registers)
• PM/DAG2 I4, I5, I6, or I7 (index registers)
M4, M5, M6, or M7 (modify registers)
! You can use any index register with any modify register from the
same DAG. You cannot pair a DAG1 register with a DAG2 register.
OUTPUT
The result register for the compute operation is always the computation
units result registers.
AR ALU operations
MR MAC operations
! instruction.
is not a MAC result register for this multifunction
SR
The destination register for both data move operations is an ALU or MAC
data register—an XOP register for the DM bus access and a YOP register for
the PM bus access.
XOP register: AX0, AX1, MX0, or MX1
YOP register: AY0, AY1, MY0, or MY1
STATUS FLAGS
The status flags generated as a result of the computation depends on the
compute operation the instruction performs.For more information, see
the status flags section of the computations reference page.
6-4 ADSP-219x Instruction Set Reference
Compute with Dual Memory Read
DETAILS
The memory read operations use register indirect addressing with post-
modify (Ireg += Mreg). For linear indirect addressing, you must initialize
the Lx register of the corresponding Ireg register to 0. For circular indirect
addressing, you must set the buffers length and base address with the cor-
responding Lreg and Breg registers. For more information on addressing,
see the ADSP-219x/2191 DSP Hardware Reference.
The DM() reference uses the 16-bit DM data bus, and the PM() reference uses
the 24-bit PM data bus. For PM data moves, the destination data register
receives the sixteen MSBs from 24-bit memory, and the PX register catches
the eight LSBs. To use all twenty-four bits of the memory data, you must
transfer the eight LSBs from PX to another data register. Otherwise, the
eight LSBs will be lost.
The address of the access, not the PM() or DM() reference, selects the mem-
ory bank. So, the DM reference could access 24-bit memory, and the PM
reference could access 16-bit memory. DM reads of 24-bit memory result in
the specified data register receiving bits 23:8 from memory. PM reads of
16-bit memory result in the specified data register receiving bits 23:8 from
memory. When the PX register is loaded using a 16-bit memory access (PM
reference to 16-bit memory or DM reference to 24-bit memory), the DSP
clears (=0)the 8-LSBs of PX.
This multifunction instruction requires the DSP to fetch three items from
memory: the instruction and two data words. The number of cycles
required to execute it depends on whether the instruction generates bus
conflicts:
Execution Conditions
1 cycle If the instruction is already cached and the data are from different memory banks
ADSP-219x Instruction Set Reference 6-5
Multifunction Instructions
Execution Conditions
2 cycles If only one bus conflict occurs—data vs. data or instruction vs. data
3 cycles If two bus conflicts occur—instruction vs. data vs. data
EXAMPLES
AR = AX0 - AY0,
MX1 = DM(I3 += M0),
MY1 = PM(I5 += M4); /* sub and dual read */
AR = AX0 + AY0,
MX0 = DM(I1 += M0),
MY0 = PM(I4 += M4); /* add and dual read */
MR = MX0 * MY0 (SS),
MX0 = DM(I2 += M2),
MY0 = PM(I7 += M7); /* mult and dual read */
SEE ALSO
• “Type 1: Compute | DregX«···DM | DregY«···PM” on page 9-21
• “ALU Instructions” on page 3-1.
• “MAC Instructions” on page 4-1.
• “Arithmetic Status (ASTAT) Register” on page 2-5
6-6 ADSP-219x Instruction Set Reference
Dual Memory Read
Dual Memory Read
AX0 = DM( I0 += M0 ) , AY0 = PM( I4 += M4 ) ;
AX1 I1 M1 AY1 I5 M5
MX0 I2 M2 MY0 I6 M6
MX1 I3 M3 MY1 I7 M7
FUNCTION
Performs two memory read operations, one over the 16-bit DM data bus
and the other over the 24-bit PM data bus.
Each read operation moves the contents of the specified memory location
to its respective destination register. The destination of both memory read
operations is an ALU or MAC data register. The DM bus read loads an ALU
or MAC DREGx register, and the PM bus read loads an ALU or MAC DREGy
register. The memory data is always right-justified in the destination data
register.
INPUT
Both data move operations use two DAG registers, index (Ireg) and mod-
ify (Mreg), to generate memory addresses—DAG1 registers for the DM bus
access, and DAG2 registers for the PM bus access. For details on DAG reg-
isters and data addressing, see “Data Move Instructions” on page 7-1.
• DM/DAG1 I0, I1, I2, or I3 (index registers)
M0, M1, M2, or M3 (modify registers)
• PM/DAG2 I4, I5, I6, or I7 (index registers)
M4, M5, M6, or M7 (modify registers)
! You can use any index register with any modify register from the
same DAG. You cannot pair a DAG1 register with a DAG2 register.
ADSP-219x Instruction Set Reference 6-7
Multifunction Instructions
OUTPUT
The destination register for both data move operations is an ALU or MAC
data register—an XOP register for the DM bus access and a YOP register for
the PM bus access.
XOP AX0, AX1, MX0, or MX1
YOP AY0, AY1, MY0, or MY1
STATUS FLAGS
None affected.
DETAILS
The memory read operations use register indirect addressing with post-
modify (Ireg += Mreg). For linear indirect addressing, you must initialize
the Lreg register of the corresponding Ireg register to 0. For circular indi-
rect addressing, you must set the buffers length and base address with the
corresponding Lreg and Breg registers. For more information on address-
ing, see the ADSP-219x/2191 DSP Hardware Reference.
The DM reference uses the 16-bit DM data bus, and the PM reference uses the
24-bit PM data bus. For PM data moves, the destination data register
receives the sixteen MSBs from 24-bit memory, and the PX register catches
the eight LSBs. To use all twenty-four bits of the memory data, you must
transfer the eight LSBs from PX to another data register. Otherwise, the
eight LSBs will be lost.
The address of the access, not the PM() or DM() reference, selects the mem-
ory bank. So, the DM() reference could access 24-bit memory, and the PM()
reference could access 16-bit memory. DM reads of 24-bit memory result in
the specified data register receiving bits 23:8 from memory. PM reads of
16-bit memory result in the specified data register receiving bits 23:8 from
memory. When the PX register is loaded using a 16-bit memory access (PM
reference to 16-bit memory or DM reference to 24-bit memory), the DSP
clears (=0)the 8-LSBs of PX.
6-8 ADSP-219x Instruction Set Reference
Dual Memory Read
This multifunction instruction requires the DSP to fetch three items from
memory: the instruction and two data words. The number of cycles
required to execute it depends on whether the instruction generates bus
conflicts:
Execution Conditions
1 cycle If the instruction is already cached and the data are from different memory banks
2 cycles If only one bus conflict occurs—data vs. data or instruction vs. data
3 cycles If two bus conflicts occur—instruction vs. data vs. data
EXAMPLES
MX0 = DM(I0 += M0),
MY0 = PM(I5 += M4); /* dual read */
AX1 = DM(I3 += M0),
AY1 = PM(I6 += M4); /* dual read */
SEE ALSO
• “Type 1: Compute | DregX«···DM | DregY«···PM” on page 9-21
ADSP-219x Instruction Set Reference 6-9
Multifunction Instructions
Compute with Memory Read
<ALU> , DREG = DM ( I0 += M0 ) ;
I1 M1
<MAC> PM
I2 M2
<SHIFT> I3 M3
I4 M4
I5 M5
I6 M6
I7 M7
FUNCTION
Combines an ALU, MAC, or shifter operation with a 16-bit read from
memory over the DM (data memory) bus. The restricted register forms—
using XOP and YOP registers, not the DREG register file—of all ALU, MAC, or
Shifter instructions are supported, except for the MAC saturate instruc-
tion, the divide primitives DIVS and DIVQ, and Shift immediate. Also, the
multifunction ALU, MAC, and Shifter instructions may not use condi-
tional (IF) options.
The compute operation executes first, using the current contents of the
data registers as input operands. Then the memory read operation exe-
cutes, overwriting the contents of the destination data register with new
data from memory.
The read operation moves the contents of the memory location to the
specified destination register. The destination of the memory read opera-
tion is an ALU, MAC, or shifter data register. The memory data is always
right-justified in the destination data register.
INPUT
Valid input operands for the compute depend on the operations compu-
tation unit. For more information, see the input descriptions in “ALU
Instructions” on page 3-1, “MAC Instructions” on page 4-1, and “Shifter
Instructions” on page 5-1.
6-10 ADSP-219x Instruction Set Reference
Compute with Memory Read
The data move operation uses two DAG registers, index (Ireg) and mod-
ify (Mreg), to generate memory addresses. Regardless of which DAG
registers are used, all accesses occur over the DM bus. For details on DAG
registers and data addressing, see “Data Move Instructions” on page 7-1.
• DAG1 I0, I1, I2, or I3 (index registers)
M0, M1, M2, or M3 (modify registers)
• DAG2 I4, I5, I6, or I7 (index registers)
M4, M5, M6, or M7 (modify registers)
! You can use any index register with any modify register from the
same DAG. You cannot pair a DAG1 register with a DAG2 register.
OUTPUT
The result register for the compute operation is always the computation
units result or feedback register.
AR/AF ALU operations
MR/SR MAC operations
SR/SE Shifter operations
The destination register for the data move operation is any register file
data register. You can use any of these data registers for the DREG
destination:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
STATUS FLAGS
The status flags generated as a result of the computation depends on the
compute operation the instruction performs.For more information, see
the status flags section of the computations reference page.
ADSP-219x Instruction Set Reference 6-11
Multifunction Instructions
DETAILS
The memory read operation uses indirect addressing with postmodify
(Ireg += Mreg) and always accesses 16-bit data over the DM bus. For linear
indirect addressing, you must initialize the Lx register of the correspond-
ing Ireg register to 0. For circular indirect addressing, you must set the
buffers length and base address with the corresponding Lreg and Breg
registers. For more information on addressing, see the ADSP-219x/2191
DSP Hardware Reference.
Since the data accesses occur over the DM data bus only, the PM() and DM()
references are semantically identical in this instruction. The address of the
access selects the memory bank, so this instruction could access 24-bit
memory. If so, the specified data register receives bits 23:8 from memory.
Since the PM() reference does not activate the PM data bus, the PX register is
not filled with any data.
This multifunction instruction requires the DSP to fetch two items from
memory: the instruction and one data word. The number of cycles
required to execute this instruction depends on whether it generates a bus
conflict:
Execution Conditions
1 cycle If no bus conflict occurs.
2 cycles If an instruction vs. data conflict occurs on the bus
EXAMPLES
AR = AX0 - AY1 + C - 1,
AX0 = DM(I1 += M0); /* ALU operation and mem read */
MR = MX1 * MY0 (SS),
SR1 = PM(I4 += M4); /* MAC operation and mem read */
AR = 3; SE = AR; /* shift code, lshift 3 bits */
6-12 ADSP-219x Instruction Set Reference
Compute with Memory Read
SI = 0xB6A3; /* value of hi word of input */
SR = ASHIFT SI (HI),
SI = DM(I0 += M0); /* ashift hi word and mem read */
AR = 3; SE = AR; /* shift code lshift 3 bits */
SI = 0x765D; /* value of lo word of input */
SR = SR OR LSHIFT SI (LO),
SI = DM(I0 += M0); /* lshift lo word and mem read */
SEE ALSO
• “Type 4: Compute | Dreg «···» DM/PM” on page 9-23
• “Type 12: Shift | Dreg «···» DM/PM” on page 9-35
• “ALU Instructions” on page 3-1
• “MAC Instructions” on page 4-1
• “Shifter Instructions” on page 5-1
• “Arithmetic Status (ASTAT) Register” on page 2-5
ADSP-219x Instruction Set Reference 6-13
Multifunction Instructions
Compute with Memory Write
DM ( I0 += M0 ) = DREG , <ALU> ;
I1 M1
PM <MAC>
I2 M2
I3 M3 <SHIFT>
I4 M4
I5 M5
I6 M6
I7 M7
FUNCTION
Combines an ALU, MAC, or shifter operation with a 16-bit write to
memory over the DM (data memory) bus. The restricted register forms—
using XOP and YOP registers, not the DREG register file—of all ALU, MAC,
and Shifter instructions are supported, except for the MAC saturate
instruction, the divide primitives DIVS and DIVQ, and Shift immediate.
Also, the multifunction ALU, MAC, and Shifter instructions may not use
conditional (IF) options.
The write operation executes first, transferring the current contents of the
data register to the specified memory location. Then the compute opera-
tion executes, overwriting the contents of the destination data register
with the result.
The source of data for the memory write operation is an ALU, MAC, or
shifter result or feedback register. The data is always right-justified in the
destination memory location.
INPUT
Valid input operands for the compute depend on the operations compu-
tation unit. For more information, see the input descriptions in “ALU
Instructions” on page 3-1, “MAC Instructions” on page 4-1, and “Shifter
Instructions” on page 5-1.
6-14 ADSP-219x Instruction Set Reference
Compute with Memory Write
The data move operation uses two DAG registers, index (Ireg) and mod-
ify (Mreg), to generate memory addresses. Regardless of which DAG
registers are used, all accesses occur over the DM bus. For details on DAG
registers and data addressing, see “Data Move Instructions” on page 7-1.
• DAG1 I0, I1, I2, or I3 (index registers)
M0, M1, M2, or M3 (modify registers)
• DAG2 I4, I5, I6, or I7 (index registers)
M4, M5, M6, or M7 (modify registers)
! You can use any index register with any modify register from the
same DAG. You cannot pair a DAG1 register with a DAG2 register.
OUTPUT
The destination register for the compute operation is always the computa-
tion units result or feedback register.
AR/AF ALU operations
MR/SR MAC operations
SR/SE Shifter operations
The source register for the data move operation is any register file data
register. You can use any of these data registers for the DREG source:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
STATUS FLAGS
The status flags generated as a result of the computation depends on the
compute operation the instruction performs.For more information, see
the status flags section of the computations reference page.
ADSP-219x Instruction Set Reference 6-15
Multifunction Instructions
DETAILS
The memory write operation uses indirect addressing with postmodify
(Ireg += Mreg) and always transfers 16-bit data over the DM bus. For linear
indirect addressing, you must initialize the Lreg register of the corre-
sponding Ireg register to 0. For circular indirect addressing, you must set
the buffers length and base address with the corresponding Lreg and Breg
registers. For more information on addressing, see the ADSP-219x/2191
DSP Hardware Reference.
Since transfers occur over the DM data bus only, the PM() and DM() refer-
ences are semantically identical in this instruction. The address of the
access selects the memory bank, so this instruction could access 24-bit
memory. If so, the operation writes bits 15:0 from the specified data regis-
ter to bits 23:8 of the specified memory location. Since the PM() reference
does not activate the PM data bus, the PX register does not supply any data.
This multifunction instruction requires the DSP to fetch one item from
memory and write one item to memory: the instruction and one data
word. The number of cycles required to execute the instruction depends
on whether it generates a bus conflict:
Execution Conditions
1 cycle If no bus conflict occurs.
2 cycles If an instruction vs. data conflict occurs on the bus
Except for SR2, you can use the same data register in both the compute
and memory write operations—as the result register for the computation
and as the source register for the data move operation.
EXAMPLES
DM(I1 += M0) = AX0,
AR = AX0 - AY1 + C - 1; /* mem write and ALU operation */
6-16 ADSP-219x Instruction Set Reference
Compute with Memory Write
PM(I4 += M4) = SR1,
MR = MX1 * MY0 (SS); /* mem write and MAC operation */
AR = 3; SE = AR; /* shift code, lshift 3 bits */
SI = 0xB6A3; /* value of hi word of input */
DM(I0 += M0) = SI,
SR = ASHIFT SI (HI); /* mem write and ashift hi word */
AR = 3; SE = AR; /* shift code lshift 3 bits */
SI = 0x765D; /* value of lo word of input */
DM(I0 += M0) = SI,
SR = SR OR LSHIFT SI (LO); /* mem write and lshift lo word */
SEE ALSO
• “Type 4: Compute | Dreg «···» DM/PM” on page 9-23
• “Type 12: Shift | Dreg «···» DM/PM” on page 9-35
• “ALU Instructions” on page 3-1
• “MAC Instructions” on page 4-1
• “Shifter Instructions” on page 5-1
• “Arithmetic Status (ASTAT) Register” on page 2-5
ADSP-219x Instruction Set Reference 6-17
Multifunction Instructions
Compute with Register to Register Move
<ALU> , DREG1 = DREG2 ;
<MAC>
<SHIFT>
FUNCTION
Combines an ALU, MAC, or shifter operation with a register to register
move. The restricted register forms—using XOP and YOP registers, not the
DREG register file—of all ALU, MAC, and Shifter instructions are sup-
ported, except for the MAC saturate instruction, the divide primitives
DIVS and DIVQ, and Shift immediate. Also, the multifunction ALU, MAC,
and Shifter instructions may not use conditional (IF) options.
The compute operation executes first, using the current contents of the
data register. Then the data move executes, overwriting the contents of the
destination data register with the contents of the source register.
The source and destination of the data move operation is an ALU, MAC,
or shifter data register. The transferred data is always right-justified in the
destination data register.
INPUT
Valid input operands for the compute depend on the operations compu-
tation unit. For more information, see the input descriptions in “ALU
Instructions” on page 3-1, “MAC Instructions” on page 4-1, and “Shifter
Instructions” on page 5-1.
6-18 ADSP-219x Instruction Set Reference
Compute with Register to Register Move
OUTPUT
The result register for the compute operation is always the computation
units result or feedback register.
AR/AF ALU operations
MR/SR MAC operations
SR/SE Shifter operations
The source (DREG2) and destination (DREG1) registers for the data move
operation are any register file data registers. You can use any of these data
registers for the DREG source and destination:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
STATUS FLAGS
The status flags generated as a result of the computation depends on the
compute operation the instruction performs. For more information, see
the status flags section of the computations reference page.
DETAILS
Except for SR2, you can use the same data register in both the compute
and data move operations—as the result register for the computation and
as the source register for the data move operation.
If you use AR as the source and destination in the data move operation
(AR = AR), the compute operation generates status only—no computation
results. For more information, see “Generate ALU Status Only: NONE”
on page 3-44.
ADSP-219x Instruction Set Reference 6-19
Multifunction Instructions
EXAMPLES
AR = AX1 + AY1, MX0 = AR; /* add and reg.-to-reg. move */
MR = MX1 * MY0 (US), MY0 = AR; /* mult and reg.-to-reg. move */
AR = 3; SE = AR; /* shift code, lshift 3 bits */
SI = 0xB6A3; /* value of hi word of input */
SR = ASHIFT SI (HI),
SI = MR0; /* ashift hi word reg move */
SEE ALSO
• “Type 8: Compute | Dreg1 «··· Dreg2” on page 9-26
• “Type 14: Shift | Dreg1 «··· Dreg2” on page 9-36
• “ALU Instructions” on page 3-1
• “MAC Instructions” on page 4-1
• “Shifter Instructions” on page 5-1
• “Arithmetic Status (ASTAT) Register” on page 2-5
6-20 ADSP-219x Instruction Set Reference

BIN
docs/9x_opcodes.pdf Normal file

Binary file not shown.

2178
docs/9x_opcodes.txt Normal file

File diff suppressed because it is too large Load Diff

BIN
docs/9x_shftops.pdf Normal file

Binary file not shown.

985
docs/9x_shftops.txt Normal file
View File

@@ -0,0 +1,985 @@
5 SHIFTER INSTRUCTIONS
Figure 5-0.
Table 5-0.
Listing 5-0.
The instruction set provides shifter instructions for performing shift oper-
ations on 16-bit input to yield 40-bit output. Combining these functions,
programs can efficiently implement numeric format control, including
full floating-point representation. Shifter operations include:
• “Arithmetic Shift” on page 5-6
• “Arithmetic Shift Immediate” on page 5-8
• “Logical Shift” on page 5-10
• “Logical Shift Immediate” on page 5-12
• “Normalize” on page 5-14
• “Normalize Immediate” on page 5-17
• “Exponent Derive” on page 5-20
• “Exponent (Block) Adjust” on page 5-23
This chapter describes the individual shifter instructions and the following
related topics:
• “Shifter Registers” on page 5-2
• “Shifter Instruction Options” on page 5-3
• “Shifter Status Flags” on page 5-5
• “Denormalization” on page 5-26
ADSP-219x Instruction Set Reference 5-1
Shifter Instructions
For details on condition codes, see “Condition Code (CCODE) Register”
on page 2-6.
Shifter Registers
As shown in Table 5-1, the shifter has five registers.
Table 5-1. Summary of shifter registers
Name Size Description
SR0 16 bits Shifter Result register (low word). SR denotes SR0, SR1, and SR2 combined,
which hold the 40-bit shifter result.
SR1 16 bits Shifter Result register (middle word). This register also functions as the mul-
tipliers y-input feedback register. SR denotes SR0, SR1, and SR2 combined,
which hold the 40-bit shifter result.
SR2 16/8 bits Shifter Result register (high byte). SR denotes SR0, SR1, and SR2 combined,
which hold the 40-bit shifter result. Although this register is 16 bits wide, for
shifter operations, only the lower eight bits are used.
SB 16/5 bits Shifter Block exponent register. Although this register is 16 bits wide, for
shifter operations, only the lower five bits are used.
Contains the effective exponent derived from the number with greatest mag-
nitude in a block of numbers. This value provides the shift code for all num-
bers in the block in subsequent NORM or xSHIFT instructions.
The value in this register is sign-extended to form a 16-bit value when trans-
ferred to memory or to other data registers.
Nonshifter instructions can use SB for a 16-bit scratch register.
5-2 ADSP-219x Instruction Set Reference
Shifter Instruction Options
Table 5-1. Summary of shifter registers (Contd)
Name Size Description
SE 16/8 bits Shifter Exponent register. Although this register is 16 bits wide, for shifter
operations, only the lower eight bits are used.
Contains the effective exponent derived from the input data. This value pro-
vides the shift code for a subsequent NORM or xSHIFT instruction.
The value in this register is sign-extended to form a 16-bit value when trans-
ferred to memory or to other data registers.
Nonshifter instructions can use SE for a 16-bit scratch register.
SI 16 bits Shifter Input register. Provides single-precision twos-complement input to
shifter instructions.
When a shifter operation writes data to SR1, it sign extends the value into
SR2, overwriting the previous contents of SR2.
The SB and SE registers are the result registers for the block exponent
adjust (EXPADJ) operation and derive exponent (EXP) operation, respec-
tively. The shifter input register SI supplies single-precision input data to
any shifter operation, except EXPADJ. To input the result from an ALU or
MAC operation directly, you use the appropriate result register—SR, AR,
or MR.
Shifter Instruction Options
Almost all shifter instructions have two to three options: (HI), (LO), and
(HIX). Each option enables a different exponent detector mode that oper-
ates only while the instruction executes. The shifter interprets and handles
the input data according to the selected mode.
For the derive exponent (EXP) and block exponent adjust ( EXPADJ) opera-
tions, the shifter calculates the shift code—the direction and number of
bits to shift—then stores that value in the SE register. For the ASHIFT,
LSHIFT, and NORM operations, the user can supply the value of the shift
ADSP-219x Instruction Set Reference 5-3
Shifter Instructions
code directly to the SE or SB registers or use the result of a previous EXP or
EXPADJ operation.
For the ASHIFT, LSHIFT, and NORM operations:
(HI) Operation references the upper half of the output field.
(LO) Operation references the lower half of the output field.
For the exponent derive (EXP) operation:
(HIX) Use this mode for shifts and normalization of results from ALU
operations.
Input data is the result of an add or subtract operation that may
have overflowed. The shifter examines the ALU overflow bit AV. If
AV=1, the effective exponent of the input is +1 (this value indicates
that overflowed occurred before the EXP operation executed). If
AV=0, no overflow occurred and the shifter performs the same oper-
ations as the (HI) mode.
(HI) Input data is a single-precision signed number or the upper half of
a double-precision signed number. The number of leading sign bits
in the input operand, which equals the number of sign bits minus
one, determines the shift code.
(By default, the EXPADJ operation always operates in this mode.)
(LO) Input data is the lower half of a double-precision signed number.
To derive the exponent on a double-precision number, you must
perform the EXP operation twice, once on the upper half of the
input, and once on the lower half. For details, “Exponent Derive”
on page 5-20.
5-4 ADSP-219x Instruction Set Reference
Shifter Status Flags
Shifter Status Flags
Two status flags in the ASTAT register, SS and SV, record the status of
shifter operations.
SS Records the sign of the shifter input operand
SS = 0 positive (+) input
SS = 1 negative () input
SV Records overflow or underflow status
SV = 0 no overflow or underflow occurred
SV = 1 overflow or underflow occurred
ADSP-219x Instruction Set Reference 5-5
Shifter Instructions
Arithmetic Shift
[IF COND] SR = [SR OR] ASHIFT DREG ( HI ) ;
LO
FUNCTION
Arithmetically shifts the bits of the operand by the amount (number of
bits) and direction specified by the shift code (value) in the SE register. A
positive value produces a left (up) shift, and a negative value produces a
right (down) shift. Optionally, the shift can be based on a half of the
32-bit output field being shifted. For more information on output
options, see “Shifter Instruction Options” on page 5-3.
If execution is based on a condition, the shifter performs the operation
only if the condition evaluates true, and it performs a NOP operation if the
condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
With the SR OR option selected, the shifter ORs the shifted output with
the current contents of the SR register and stores that value in SR. Other-
wise, it overwrites the current contents of the SR register with the shifted
output.
INPUT
The input operand, the value to shift, is supplied in a data register. You
can use any of these data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
OUTPUT
SR Shifter result register contains 40-bit result.
5-6 ADSP-219x Instruction Set Reference
Arithmetic Shift
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
SV AZ, AN, AV, AC, AS, AQ, SS, MV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
The shifter sign-extends the 40-bit result to the left, replicating the MSB
of the input, and it zero-fills the 40-bit result from the right. Bits shifted
out past either boundary (SR39 or SR0) are dropped.
To shift a double-precision number, you shift both halves of the input
data separately, using the same shift code value for both halves. You
ASHIFT the upper half of the input data but LSHIFT the lower half. The
first cycle, you ASHIFT the upper half of the input using the (HI) option.
The second cycle, you LSHIFT the lower half using both the (LO) and SR OR
options. Using these options prevents the shifter from sign-extending the
MSB of the low word and from overwriting the output (upper word) from
the previous ASHIFT operation.
EXAMPLES
AR = 3; SE = AR; /* shift code, left shift 3 bits */
SI = 0xB6A3; /* value of upper word of input data */
SR = ASHIFT SI (HI); /* arithmetically shift high word */
SEE ALSO
• “Type 16: Shift Reg0” on page 9-38
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
ADSP-219x Instruction Set Reference 5-7
Shifter Instructions
Arithmetic Shift Immediate
SR = [SR OR] ASHIFT DREG BY <imm8> ( HI ) ;
LO
FUNCTION
Arithmetically shifts the bits of the operand by the amount (number of
bits) and direction specified by the immediate value. Valid immediate val-
ues range from 128 to 127. A positive value produces a left (up) shift, and
a negative value produces a right (down) shift. Optionally, the shift can be
based on a half of the 32-bit output field being shifted. For more informa-
tion on output options, see “Shifter Instruction Options” on page 5-3.
With the SR OR option selected, the shifter ORs the shifted output with
the current contents of the SR register and stores that value in SR. Other-
wise, it overwrites the current contents of the SR register with the shifted
output.
INPUT
The input operand, the value to shift, is supplied in a data register. You
can use any of these data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
OUTPUT
SR Shifter result register contains 40-bit result.
5-8 ADSP-219x Instruction Set Reference
Arithmetic Shift Immediate
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
SV AZ, AN, AV, AC, AS, AQ, SS, MV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
The shifter sign-extends the 40-bit result to the left, replicating the MSB
of the input, and it zero-fills the 40-bit result from the right. Bits shifted
out past either boundary (SR39 or SR0) are dropped.
To shift a double-precision number, you shift both halves of the input
data separately, using the same immediate value for both halves. You ASH-
IFT the upper half of the input data but LSHIFT the lower half. The first
cycle, you ASHIFT the upper half of the input using the (HI) option. The
second cycle, you LSHIFT the lower half using both the (LO) and SR OR
options. Using these options prevents the shifter from sign-extending the
MSB of the low word and from overwriting the output (upper word) from
the previous ASHIFT operation.
EXAMPLES
SI = 0xB6A3; /* value of upper word of input data */
SR = ASHIFT SI BY 3 (HI);/* arithmetically shift upper word */
SEE ALSO
• “Type 15: Shift Data8” on page 9-37
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
ADSP-219x Instruction Set Reference 5-9
Shifter Instructions
Logical Shift
[IF COND] SR = [SR OR] LSHIFT DREG ( HI ) ;
LO
FUNCTION
Logically shifts the bits of the operand by the amount (number of bits)
and direction specified by the shift code (value) in the SE register. A posi-
tive value produces a left (up) shift, and a negative value produces a right
(down) shift. Optionally, the shift can be based on a half of the 32-bit
output field being shifted. For more information on output options, see
“Shifter Instruction Options” on page 5-3.
If execution is based on a condition, the shifter performs the operation
only if the condition evaluates true, and it performs a NOP operation if the
condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
With the SR OR option selected, the shifter ORs the shifted output with
the current contents of the SR register and stores that value in SR. Other-
wise, it overwrites the current contents of the SR register with the shifted
output.
INPUT
The input operand, the value to shift, is supplied in a data register. You
can use any of these data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
OUTPUT
SR Shifter result register contains 40-bit result.
5-10 ADSP-219x Instruction Set Reference
Logical Shift
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
SV AZ, AN, AV, AC, AS, AQ, SS, MV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
For left shifts (positive shift code), the shifter zero-fills the 40-bit result
from the right. Bits shifted out past the high-order boundary (SR39) are
dropped.
For right shifts (negative shift code), the shifter zero-fills the 40-bit result
from the left. Bits shifted out past the low-order boundary (SR0) are
dropped.
To shift a double-precision number, you shift both halves of the input
data separately, using the same shift code value for both halves. The first
cycle, you LSHIFT the upper half of the input using the (HI) option. The
second cycle, you LSHIFT the lower half using both the (LO) and SR OR
options. Using these options prevents the shifter from overwriting the
result (upper word) from the previous LSHIFT operation.
EXAMPLES
AR = 3; SE = AR; /* shift code left shift 3 bits */
AX0 = 0x765D; /* value of lower word of input data */
SR = SR OR LSHIFT AX0(LO);/* logically shift low word */
SEE ALSO
• “Type 16: Shift Reg0” on page 9-38
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
ADSP-219x Instruction Set Reference 5-11
Shifter Instructions
Logical Shift Immediate
SR = [SR OR] LSHIFT BY <imm8> ( HI ) ;
LO
FUNCTION
Logically shifts the bits of the operand by the amount (number of bits)
and direction specified by the immediate value. Valid immediate values
range from 128 to 127. A positive value produces a left (up) shift, and a
negative value produces a right (down) shift. Optionally, the shift can be
based on a half of the 32-bit output field being shifted. For more informa-
tion on output options, see “Shifter Instruction Options” on page 5-3.
With the SR OR option selected, the shifter ORs the shifted output with
the current contents of the SR register and stores that value in SR. Other-
wise, it overwrites the current contents of the SR register with the shifted
output.
INPUT
The input operand, the value to shift, is supplied in a data register. You
can use any of these data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
OUTPUT
SR Shifter result register contains 40-bit result.
5-12 ADSP-219x Instruction Set Reference
Logical Shift Immediate
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
SV AZ, AN, AV, AC, AS, AQ, SS, MV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
For left shifts (positive shift code), the shifter zero-fills the 40-bit result
from the right. Bits shifted out past the high-order boundary (SR39) are
dropped.
For right shifts (negative shift code), the shifter zero-fills the 40-bit result
from the left. Bits shifted out past the low-order boundary (SR0) are
dropped.
To shift a double-precision number, you shift both halves of the input
data separately, using the same shift code value for both halves. The first
cycle, you LSHIFT the upper half of the input using the (HI) option. The
second cycle, you LSHIFT the lower half using both the (LO) and SR OR
options. Using these options prevents the shifter from overwriting the
result (upper word) from the previous LSHIFT operation.
EXAMPLES
SI = 0xFF6A; /* single-precision input */
SR = SR OR LSHIFT SI BY 3 (LO); /* logically shift low word */
SEE ALSO
• “Type 15: Shift Data8” on page 9-37
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
ADSP-219x Instruction Set Reference 5-13
Shifter Instructions
Normalize
[IF COND] SR = [SR OR] NORM DREG ( HI ) ;
LO
FUNCTION
Normalization, in essence, is a fixed- to floating-point conversion opera-
tion that produces an exponent and a mantissa. Optionally, the operation
can be based on a half of the 32-bit output field being shifted. For more
information on output options, see “Shifter Instruction Options” on page
5-3.
Normalization using this instruction is a two step process that requires:
• The EXP instruction to derive the exponent for the shift code.
• The NORM instruction to shift the twos-complement input by the cal-
culated shift code, removing its redundant sign bits and aligning its
true sign bit to the high-order bit of the output field.
The EXP operation calculates the number of redundant sign bits in the
input and stores the negative of that value in SE. The NORM operation
negates the value in SE again to generate a positive shift code, ensuring
that the input is shifted left.
If execution is based on a condition, the shifter performs the operation
only if the condition evaluates true, and it performs a NOP operation if the
condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
With the SR OR option selected, the shifter ORs the shifted output with
the current contents of the SR register and stores that value in SR. Other-
wise, it overwrites the current contents of the SR register with the shifted
output.
5-14 ADSP-219x Instruction Set Reference
Normalize
INPUT
The input operand, the value to shift, is supplied in a data register. You
can use any of these data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
OUTPUT
SR Shifter result register contains 40-bit result.
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
SV AZ, AN, AV, AC, AS, AQ, SS, MV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
The (HI) and (LO) options determine how unused bits in the 40-bit out-
put are filled. When the (HI) option is selected, the shifter zero-fills the
40-bit result from the right. When the (LO) option is selected, the shifter
zero-fills the 40-bit result to the left. Bits shifted out past the high-order
boundary (SR39) are dropped.
To normalize a double-precision number, you normalize both halves of
the input data separately, using the same shift code value for both halves.
First, you use the EXP instruction to derive the exponent to use for the
shift code. Then, in the first normalization cycle, you NORM the upper half
of the input using the (HI) option. The next cycle, you NORM the lower half
using both the (LO) and SR OR options. Using these options prevents the
ADSP-219x Instruction Set Reference 5-15
Shifter Instructions
shifter from overwriting the result (upper word) from the previous NORM
operation.
EXAMPLES
/* Normalize double-precision twos complement data: */
AX1 = 0xF6D4; /* load hi 2s comp data in dreg */
AX0 = 0x04A2; /* load lo 2s comp data in dreg */
SE = EXP AX1 (HI); /* derive exponent on hi word */
SE = EXP AX0 (LO); /* derive exponent on lo word */
SR = NORM AX1 (HI); /* normalize hi word */
SR = SR OR NORM AX0 (LO); /* normalize lo word */
SEE ALSO
• “Type 16: Shift Reg0” on page 9-38
• “Denormalization” on page 5-26
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
5-16 ADSP-219x Instruction Set Reference
Normalize Immediate
Normalize Immediate
SR = [SR OR] NORM DREG BY <imm8> ( HI ) ;
LO
FUNCTION
Normalization, in essence, is a fixed- to floating-point conversion opera-
tion that produces an exponent and a mantissa. Using a positive constant
for the shift code, it is a one step process that shifts the twos-complement
input left by the specified amount, removing its redundant sign bits and
aligning its true sign bit to the high-order bit of the output field. Option-
ally, the operation can be based on a half of the 32-bit output field being
shifted. For more information on output options, see “Shifter Instruction
Options” on page 5-3.
With the SR OR option selected, the shifter ORs the shifted output with
the current contents of the SR register and stores that value in SR. Other-
wise, it overwrites the current contents of the SR register with the shifted
output.
INPUT
The input operand, the value to shift, is supplied in a data register. You
can use any of these data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
OUTPUT
SR Shifter result register contains 40-bit result.
ADSP-219x Instruction Set Reference 5-17
Shifter Instructions
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
SV AZ, AN, AV, AC, AS, AQ, SS, MV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
The (HI) and (LO) options determine how unused bits in the 40-bit out-
put are filled. When the (HI) option is selected, the shifter zero-fills the
40-bit result from the right. When the (LO) option is selected, the shifter
zero-fills the 40-bit result to the left. Bits shifted out past the high-order
boundary (SR39) are dropped.
To normalize a double-precision number, you normalize both halves of
the input data separately, using the immediate value for both halves. In
the first normalization cycle, you NORM the upper half of the input using
the (HI) option. The next cycle, you NORM the lower half using both the
(LO) and SR OR options. Using these options prevents the shifter from
overwriting the result (upper word) from the previous NORM operation.
EXAMPLES
/* Normalize a double-precision, twos-complement data: */
AX1 = 0xF6D4; /* load hi 2s comp data in dreg */
AX0 = 0x04A2; /* load lo 2s comp data in dreg */
SR = NORM AX1 BY 2 (HI); /* normalize hi word */
SR = SR OR NORM AX0 BY 2 (LO);/* normalize lo word */
SEE ALSO
• “Type 15: Shift Data8” on page 9-37
• “Denormalization” on page 5-26
5-18 ADSP-219x Instruction Set Reference
Normalize Immediate
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
ADSP-219x Instruction Set Reference 5-19
Shifter Instructions
Exponent Derive
[IF COND] SE = EXP DREG ( HIX ) ;
HI
LO
FUNCTION
Derives the effective exponent of the input operand to generate the shift
code value for use in a subsequent normalization operation. The instruc-
tion option, (HIX), (HI), or (LO), determines the resulting shift code. For
more information on output options, see “Shifter Instruction Options” on
page 5-3.
If execution is based on a condition, the shifter performs the operation
only if the condition evaluates true, and it performs a NOP operation if the
condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
INPUT
The input operand, the value to shift, is supplied in a data register. You
can use any of these data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
OUTPUT
SE Shifter exponent register contains the 8-bit shift code.
5-20 ADSP-219x Instruction Set Reference
Exponent Derive
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
SS (Affected by operations using the (HI) and AZ, AN, AV, AC, AS, AQ, MV, SV
(HIX) options only. Set by the MSB of the input
data when AV = 0. In (HIX) mode only, set by the
inverted MSB of the input data when AV = 1.)
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
You use the (LO) option only to derive the exponent for the low word in a
double-precision twos-complement number. But before you do, you must
derive the exponent on the high word using either the (HI) or the (HIX)
option. The result of the EXP operation on the upper half determines the
shift code of the lower half. Unless the upper half contains all sign bits,
the SE register contains the correct shift code to use for both EXP (HI/HIX)
and (LO) operations. If the upper half does contain all sign bits, EXP (LO)
totals the number of sign bits in the double-precision word and stores that
value in SE.
EXAMPLES
/* Normalize double-precision twos complement data: */
AX1 = 0xF6D4; /* load hi 2s comp data in dreg */
AX0 = 0x04A2; /* load lo 2s comp data in dreg */
SE = EXP AX1 (HI); /* derive exponent on hi word */
SE = EXP AX0 (LO); /* derive exponent on lo word */
SR = NORM AX1 (HI); /* normalize hi word */
SR = SR OR NORM AX0 (LO); /* normalize lo word */
ADSP-219x Instruction Set Reference 5-21
Shifter Instructions
SEE ALSO
• “Type 16: Shift Reg0” on page 9-38
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
5-22 ADSP-219x Instruction Set Reference
Exponent (Block) Adjust
Exponent (Block) Adjust
[IF COND] SB = EXPADJ DREG ;
FUNCTION
Derives the effective exponent of the number of largest magnitude in a
block of numbers. Using this value for the shift code in subsequent NORM
instructions, you can normalize each number in the block.
If execution is based on a condition, the shifter performs the operation
only if the condition evaluates true, and it performs a NOP operation if the
condition evaluates false. Omitting the condition forces unconditional
execution of the instruction.
INPUT
The input operand, the value to shift, is supplied in a data register. You
can use any of these data registers for the DREG inputs:
Register File
AX0, AX1, AY0, AY1, AR, MX0, MX1, MY0, MY1, MR0, MR1, MR2, SR0, SR1, SR2, SI
OUTPUT
SB Shifter block exponent register contains the 5-bit exponent value.
You must initialize SB to 16 before issuing the first EXPADJ instruc-
tion in the series.
ADSP-219x Instruction Set Reference 5-23
Shifter Instructions
STATUS FLAGS
Affected Flagsset or cleared by the operation Unaffected Flags
AZ, AN, AV, AC, AS, AQ, SS, MV, SV
For information on these status bits in the ASTAT register, see Table 2-2 on page 2-5.
DETAILS
This instruction operates in (HI) mode to derive the exponent. It works
on double-precision twos-complement input only. Possible values for the
result of the EXPADJ operation range from 15 to 0.
To derive the effective exponent for a block of numbers, you
1. Initialize the SB register to 16.
SB = 16;
This value falls below the range of possible exponent values.
2. For each number in the block, derive the effective exponent.
SB = EXPADJ DREGx;
For the first operation, the shifter derives the exponent and stores it
in SB.
For each subsequent operation, the shifter derives the exponent
and compares the new value with the current value of SB. If the
new value is greater than the current value, the shifter stores the
new value in SB, overwriting the old value. Otherwise, the shifter
discards the new value and the contents of SB remain unchanged.
At the end of the last EXPADJ operation, SB contains the exponent
of the number of largest magnitude in the block.
5-24 ADSP-219x Instruction Set Reference
Exponent (Block) Adjust
3. Transfer the contents of SB to SE.
SE = SB;
SE now contains the shift code to use in subsequent NORM opera-
tions to normalize each of the numbers in the block. For details,
see “Normalize” on page 5-14.
Alternatively, you can save the exponent in a data register for use
later in your program.
EXAMPLES
/* Normalize double-precision twos complement data: */
AX1 = 0xF6D4; /* load hi 2s comp data in dreg */
AX0 = 0x04A2; /* load lo 2s comp data in dreg */
SB = -16; /* initialize SB */
SB = EXPADJ AX1;
SB = EXPADJ AX0;
SE = SB; /* load block adjusted exp */
SR = NORM AX1 (HI); /* normalize hi word */
SR = SR OR NORM AX0 (LO); /* normalize lo word */
SEE ALSO
• “Type 16: Shift Reg0” on page 9-38
• “Condition Code (CCODE) Register” on page 2-6
• “Mode Status (MSTAT) Register” on page 2-11
ADSP-219x Instruction Set Reference 5-25
Shifter Instructions
Denormalization
FUNCTION
Denormalization is a shift function in which a predefined exponent
defines the amount and direction of the shift. In essence, denormalization
is a floating- to fixed-point conversion operation. It requires a series of
shifter operations:
• The EXP instruction to derive the exponent used for the shift code,
or SE explicitly loaded with the exponent value. SE must contain the
shift value; for denormalization, you cannot use ASHIFT/LSHIFT
with an immediate value.
• The ASHIFT instruction to shift a single-precision number or the
high word of a double-precision number.
• When denormalizing a double-precision number, the LSHIFT
instruction to shift the low word.
Denormalize a double-precision, twos-complement number:
MX1 = 3; /* generate shift code */
SE = MX1; /* load value in SE register */
AX1 = 0xB6A3; /* load high word of input */
AX0 = 0x765D; /* load low word of input */
SR = ASHIFT AX1(HI); /* arith shift high word */
SR = SR OR LSHIFT AX0(LO); /* logically shift low word */
You can reverse shift order, but you must always arithmetically shift the
high word of a double-precision number:
MX1 = 3; /* generate shift code */
SE = MX1; /* load value in SE register */
AX1 = 0xB6A3; /* load high word of input */
AX0 = 0x765D; /* load low word of input */
SR = LSHIFT AX0(LO); /* logically shift low word */
SR = SR OR ASHIFT AX1(HI); /* arith shift high word */
5-26 ADSP-219x Instruction Set Reference

34
docs/ARCHITECTURE.md Normal file
View File

@@ -0,0 +1,34 @@
# ADSP-219x Architecture Reference ⚙️
## Core Features
The ADSP-219x family consists of a 16-bit fixed-point DSP core with a 24-bit instruction word.
- **Harvard Architecture**: Separate Program Memory (PM) and Data Memory (DM) buses.
- **Instruction Width**: Exactly 24 bits. Padded often with a leading 0x00 or trailing zero byte if stored in 32-bit words, or packed as 3 bytes.
- **Memory Model**:
- PM Adressraum (24-bit Wörter): 16-bit to 24-bit depending on the model.
- DM Adressraum (16-bit Wörter): Up to 64K words.
## Register Set 🗳️
| Group | Registry | Purpose |
|-------|----------|---------|
| **REG0** | AX0, AX1, MX0, MX1, AY0, AY1, MY0, MY1, MR2, SR2, AR, SI, MR1, SR1, MR0, SR0 | ALU, Multiplier, MAC, and Shifter registers. |
| **REG1** | I0-I3, M0-M3, L0-L3, IMASK, IRPTL, ICNTL, STACKA | DAG1 (Data Address Generator) indices, modifies, lengths, and interrupt control. |
| **REG2** | I4-I7, M4-M7, L4-L7, Reserved, CNTR, LPSTACKA | DAG2 indices, modifies, lengths, and hardware loop structures. |
| **REG3** | ASTAT, MSTAT, SSTAT, LPSTACKP, CCODE, SE, SB, PX, DMPG1, DMPG2, IOPG, IJPG, Reserved, STACKP | Status registers, page registers, and control stacks. |
## Arithmetic Elements
- **ALU**: 16-bit with overflow and saturation logic.
- **Multiplier/MAC**: 16x16 → 40-bit accumulation (MR).
- **Barrel Shifter**: 32-bit with 16-bit input and bit-manipulation capabilities.
## Instruction Types 🕹️
There are ~37 distinct instruction types, distinguished by their MSB encoding.
- **Type 1**: Compute + Dual Memory Read (Multifunction).
- **Type 3**: Direct Register Read/Write.
- **Type 4**: Compute + Single Memory Read/Write.
- **Type 6/7**: Load Immediate 16-bit to Register.
- **Type 10/10a/19/36**: Jumps and Calls (Relative/Indirect/Long).
- **Type 15/16**: Shifter operations.

26
docs/GETTING_STARTED.md Normal file
View File

@@ -0,0 +1,26 @@
# ADSP-219x Analysis Workflow (Air-Gapped 🛡️)
## Phase 1: Preparation (Online)
1. **Download and Copy**: Ensure the entire `adsp219x-re/` folder is on the air-gapped machine.
2. **Setup Dependencies**: Ensure Python 3.8+ is installed. Radare2 must be on $PATH.
3. **Verify Python**: `python3 -m pip install r2pipe` (if not already part of your r2 install).
## Phase 2: Loading ROMs
Use raw loading for ADSP-2191 ROMs:
`r2 -a adsp2 -b 24 -m 0x0 my_rom.bin`
(Note: `-a` and `-b` are placeholders until a native plugin exists. We use raw mode.)
## Phase 3: Automated Disassembly
Run the standalone disassembler first to get a quick overview:
`python3 disassembler/adsp219x_disasm.py my_rom.bin 3 > disassembly.txt`
## Phase 4: Radare2 + Iaito Integration
To use our custom Python disassembly inside radare2:
1. Open the ROM in radare2.
2. Run the analysis script via r2pipe:
`#!python analysis/analyze_rom.py` (Inside r2: `#!pipe python3 ...`)
3. Use `iaito` to browse the memory with the comments generated by the script.
## Phase 5: Debugging/Validation
Compare your proprietary ROM against our test ROMs in `testrom/test_roms/`.
If you find a new instruction type, add it to `disassembler/adsp219x_disasm.py` and submit!

1366
docs/opcode_definitions.txt Normal file

File diff suppressed because it is too large Load Diff

812
docs/opcode_mnemonics.txt Normal file
View File

@@ -0,0 +1,812 @@
9 INSTRUCTION OPCODES
Figure 9-0.
Table 9-0.
Listing 9-0.
This chapter lists and describes the opcodes that defines each of the
instructions in the ADSP-219xs instruction set. This information is use-
ful for debugging programs.
This chapter covers the following topics:
• “Opcode Mnemonics” on page 9-1
• “Opcode Definitions” on page 9-20
Opcode Mnemonics
This section lists, describes, and gives the numeric value for each opcode
mnemonic.
Table 9-1. Opcode mnemonics
Mnemonic Description Details
AMF Specifies an ALU or multiplier operation. page 9-8
AS Specifies whether ALU saturation mode is page 9-40
0 = disabled
1 = enabled
B Specifies whether branch is page 9-32
page 9-41
0 = immediate
page 9-42
1 = delayed
ADSP-219x Instruction Set Reference 9-1
Instruction Opcodes
Table 9-1. Opcode mnemonics (Contd)
Mnemonic Description Details
BIT Specifies which interrupt to enable or disable (015). page 9-60
BO Specifies whether the supplied 4-bit constant in a type 9 instruction is page 9-12
page 9-27
01 = as is
11 = negated
BR Specifies whether bit-reverse addressing on DAG1 is page 9-40
0 = disabled
1 = enabled
BSR Specifies whether the secondary DAG address registers are page 9-40
0 = disabled
1 = enabled
C Specifies whether a software interrupt is page 9-60
0 = set
1 = cleared
CC Specifies the two LSBs of a 4-bit constant value in a type 9 instruction. page 9-12
page 9-27
CF Specifies whether to flush the instruction cache page 9-50
0 = No flush
1 = flush
COND Specifies one of the condition codes on which to base execution of the page 9-11
instruction.
9-2 ADSP-219x Instruction Set Reference
Table 9-1. Opcode mnemonics (Contd)
Mnemonic Description Details
D Specifies the direction of a data move. page 9-22
page 9-35
0 = read
page 9-51
1 = write page 9-54
page 9-57
page 9-58
DD Specifies a destination data register for a DM bus transfer. page 9-21
00 = AX0
01 = AX1
10 = MX0
11 = MX1
DDREG Specifies a destination register for a register-to-register move operation. page 9-13
DREG Specifies an unrestricted data register (REG0 only). page 9-13
DMI Specifies a DAG index address register (I0I3) for a DM bus transfer. page 9-18
page 9-21
DMM Specifies a DAG modify address register (M0M3) for a DM bus trans- page 9-18
fer. page 9-21
DRGP Specifies a destination register group. page 9-39
00 = REG0
01 = REG1
10 = REG2
11 = REG3
DRL Specifies two MSBs of DREG data register address. page 9-13
DRU Specifies two LSBs of DREG data register address. page 9-13
Exponent Specifies an 8-bit, twos-complement shift value. page 9-37
ADSP-219x Instruction Set Reference 9-3
Instruction Opcodes
Table 9-1. Opcode mnemonics (Contd)
Mnemonic Description Details
G Specifies a DAG register group. page 9-17
0 = DAG1
1 = DAG2
IREG/MREG Specifies DAG index and modify registers (I0I7, M0M7). page 9-18
I Specifies DAG index register (I0I7). page 9-17
Idle Value Specifies a 4-bit value that defines an internal clock divisor. page 9-53
INT Specifies whether interrupts are globally page 9-40
0 = disabled
1 = enabled
LPP Specifies push/pop of the loop stacks. page 9-50
0 = disabled
1 = enabled
M Specifies a DAG modify register. page 9-17
MM Specifies whether MAC integer mode is page 9-40
0 = disabled
1 = enabled
MOD DATA Specifies an 8-bit, twos-complement immediate data value. page 9-44
page 9-51
MS Specifies memory bus for a memory data transfer page 9-54
0 = 16-bit DM bus
1 = 24-bit PM bus
9-4 ADSP-219x Instruction Set Reference
Table 9-1. Opcode mnemonics (Contd)
Mnemonic Description Details
OL Specifies whether ALU overflow mode is page 9-40
0 = disabled
1 = enabled
PD Specifies a destination data register for a PM bus transfer. page 9-21
00 = AY0
01 = AY1
10 = MY0
11 = MY1
PMI Specifies a DAG index address register (I4I7) for a PM bus transfer. page 9-18
PMM Specifies a DAG modify address register (M4M7) for a PM bus trans- page 9-18
fer.
PPP Specifies push/pop of the PC stack. page 9-50
0 = disabled
1 = enabled
Q Specifies the RTI mode. page 9-42
0 = normal
1 = single-step
R Specifies a result register. page 9-49
0 = MR register
1 = SR register
REG Specifies a core register of RGPx. page 9-13
REG1 Specifies a register group 1 register page 9-13
page 9-25
ADSP-219x Instruction Set Reference 9-5
Instruction Opcodes
Table 9-1. Opcode mnemonics (Contd)
Mnemonic Description Details
REG2 Specifies a register group 2 register page 9-13
page 9-25
REG3 Specifies a register group 3 register page 9-13
page 9-56
RGP Specifies a register group. page 9-13
00 = REG0
01 = REG1
10 = REG2
11 = REG3.
S Specifies the branch type. page 9-32
page 9-41
0 = jump
1 = call
SDREG Specifies the source data register for a data move operation. page 9-13
SF Specifies a shift function. page 9-15
SPP Specifies push/pop of the status stack. page 9-50
0 = disabled
1 = enabled
SR Specifies whether the secondary data registers are page 9-40
0 = disabled
1 = enabled
9-6 ADSP-219x Instruction Set Reference
Table 9-1. Opcode mnemonics (Contd)
Mnemonic Description Details
SRGP Specifies a source register group for a data move operation. page 9-39
00 = REG0
01 = REG1
10 = REG2
11 = REG3
SWCD Specifies a 4-bit nonfunctional value used by ADI tools only. page 9-52
T Specifies the return type. page 9-42
0 = RTS
1 = RTI
TERM Specifies the terminating condition for the type 11 instruction. page 9-34
1110 = NOT CE
1111 = TRUE
TI Specifies whether the timer is page 9-40
0 = disabled
1 = enabled
U Specifies whether the DAG index register is page 9-54
0 = premodified with no update
1 = postmodified with update
XOP Specifies a restricted data register used to supply the x operand value in page 9-19
a multifunction or conditional instruction.
XREG Specifies the source register (REG0) in a shift function. page 9-13
ADSP-219x Instruction Set Reference 9-7
Instruction Opcodes
Table 9-1. Opcode mnemonics (Contd)
Mnemonic Description Details
Y0 Specifies whether the source of the x-operand is page 9-11
0 = data register
1 = 0 (explicit value)
YOP Specifies a restricted data register used to supply the y operand value in page 9-19
a multifunction or conditional instruction.
YREG Specifies the destination register (REG0) in a shift function. page 9-13
page 9-11
YY Specifies the two MSBs of a 4-bit constant value in a type 9 instruc- page 9-12
tion. page 9-27
Z Specifies a result or feedback register page 9-23
page 9-26
0 = result register
page 9-27
1 = feedback register page 9-11
ALU or Multiplier Function (AMF) Codes
Table 9-2 on page 9-9 lists the AMF codes used by these instruction types:
• “Type 1: Compute | DregX«···DM | DregY«···PM” on page 9-21
• “Type 4: Compute | Dreg «···» DM/PM” on page 9-23
• “Type 8: Compute | Dreg1 «··· Dreg2” on page 9-26
• “Type 9: Compute” on page 9-27
9-8 ADSP-219x Instruction Set Reference
Table 9-2. ALU/multiplier function (AMF) codes
Code Function Description
Multiplier functions
00000 NOP No operation
00001 X * Y (RND) Multiply
00010 MR + X * Y (RND) Multiply and accumulate
00011 MR X * Y (RND) Multiply and subtract
00100 X * Y (SS) Multiply
00101 X * Y (SU) Multiply
00110 X * Y (US) Multiply
00111 X * Y (UU) Multiply
01000 MR + X * Y (SS) Multiply and accumulate
01001 MR + X * Y (SU) Multiply and accumulate
01010 MR + X * Y (US) Multiply and accumulate
01011 MR + X * Y (UU) Multiply and accumulate
01100 MR X * Y (SS) Multiply and subtract
01101 MR X * Y (SU) Multiply and subtract
01110 MR X * Y (US) Multiply and subtract
01111 MR X * Y (UU) Multiply and subtract
(RND) = round results; (SS) = both operands signed; (SU) = x operand signed, y operand unsigned;
(US) =x operand unsigned, y operand signed; (UU) = both operands unsigned
ADSP-219x Instruction Set Reference 9-9
Instruction Opcodes
Table 9-2. ALU/multiplier function (AMF) codes (Contd)
Code Function Description
ALU functions
10000 Y PASS/CLEAR
10001 Y+1 PASS
10010 X+Y+C Add with carry
10011 X+Y Add
10100 NOT Y Negate
10101 Y PASS
10110 XY+C1 Subtract (XY) with borrow
10111 XY Subtract
11000 Y1 PASS
11001 YX Subtract
11010 YX+C1 Subtract (YX) with borrow
11011 NOT X Negate
11100 X AND Y AND/test bit,clear bit
11101 X OR Y OR/set bit
11110 X XOR Y XOR/toggle bit
11111 ABS X Absolute value
(RND) = round results; (SS) = both operands signed; (SU) = x operand signed, y operand unsigned;
(US) =x operand unsigned, y operand signed; (UU) = both operands unsigned
9-10 ADSP-219x Instruction Set Reference
Condition Codes
Table 9-3 on page 9-11 lists the condition codes used by these instruction
types:
• “Type 9: Compute” on page 9-27
• “Type 10: Direct Jump” on page 9-32
• “Type 16: Shift Reg0” on page 9-38
• “Type 19: Indirect Jump/Call” on page 9-41
• “Type 20: Return” on page 9-42
• “Type 36: Long Jump/Call” on page 9-59
• “Type 11: Do ··· Until” on page 9-34
uses NOT CE and TRUE only for the terminating condition.
Table 9-3. Condition codes
Code Condition Description
0000 EQ Equal to 0 (= 0)
0001 NE Not equal to 0 (≠ 0)
0010 GT Greater than 0 (>0)
0011 LE Less than or equal to 0 (≤0)
0100 LT Less than 0 (<0)
0101 GE Greater than or equal to 0 (≥0)
0110 AV ALU overflow
0111 NOT AV Not ALU overflow
ADSP-219x Instruction Set Reference 9-11
Instruction Opcodes
Table 9-3. Condition codes (Contd)
Code Condition Description
1000 AC ALU carry
1001 NOT AC Not ALU carry
1010 SWCOND CCODE register condition
1011 NOT SWCOND Not CCODE register condition
1100 MV MAC overflow
1101 NOT MV Not MAC overflow
1110 NOT CE Counter not expired
1111 TRUE Always true
Constant Codes
Table 9-4 lists the valid constants used by “Type 9: Compute” on
page 9-27. As shown, the YY/CC bits determine the constant value and the
BO bits determine the sign of the value.
Table 9-4. Constants
Code Decimal / Hex Decimal / Hex
YY CC BO = 01 BO = 11
00 00 1 / 0x0001 2 / 0xFFFE
00 01 2 / 0x0002 3 / 0xFFFD
00 10 4 / 0x0004 5 / 0xFFFB
00 11 8 / 0x0008 9 / 0xFFF7
9-12 ADSP-219x Instruction Set Reference
Table 9-4. Constants (Contd)
Code Decimal / Hex Decimal / Hex
YY CC BO = 01 BO = 11
01 00 16 / 0x0010 17 / 0xFFEF
01 01 32 / 0x0020 33 / 0xFFDF
01 10 64 / 0x0040 65 / 0xFFBF
01 11 128 / 0x0080 129 / 0xFF7F
10 00 256 / 0x0100 257 / 0xFEFF
10 01 512 / 0x0200 513 / 0xFDFF
10 10 1024 / 0x0400 1025 / 0xFBFF
10 11 2048 / 0x0800 2049 / 0xF7FF
11 00 4096 / 0x1000 4097 / 0xEFFF
11 01 8192 / 0x2000 8193 / 0xDFFF
11 10 16384 / 0x4000 16385 / 0xBFFF
11 11 32768 / 0x8000 +32767 / 0x7FFF
Core Register Codes
Table 9-5 on page 9-14 list the core registers and their addresses. The
complete address of any individual register is formed by appending the
registers address bits to its RGP bits, so, for example, the address of the I2
register is 010010. The opcode mnemonics DREG, DDREG, SDREG, XREG, and
YREG and the following instruction types reference these registers by their
address bits:
• “Type 3: Dreg/Ireg/Mreg «···» DM/PM” on page 9-22
ADSP-219x Instruction Set Reference 9-13
Instruction Opcodes
• “Type 4: Compute | Dreg «···» DM/PM” on page 9-23
• “Type 6: Dreg «··· Data16” on page 9-24
• “Type 8: Compute | Dreg1 «··· Dreg2” on page 9-26
• “Type 9: Compute” on page 9-27
• “Type 12: Shift | Dreg «···» DM/PM” on page 9-35
• “Type 14: Shift | Dreg1 «··· Dreg2” on page 9-36
• “Type 15: Shift Data8” on page 9-37
• “Type 16: Shift Reg0” on page 9-38
• “Type 17: Any Reg «··· Any Reg” on page 9-39
• “Type 34: Dreg «···» IOreg” on page 9-57
• “Type 35: Dreg «···»Sreg” on page 9-58
Table 9-5. Core registers
RGP/Address Register Groups (RGP)
Address 00 (REG0) 01 (REG1) 10 (REG2) 11 (REG3)
0000 AX0 I0 I4 ASTAT
0001 AX1 I1 I5 MSTAT
0010 MX0 I2 I6 SSTAT
0011 MX1 I3 I7 LPSTACKP
0100 AY0 M0 M4 CCODE
0101 AY1 M1 M5 SE
0110 MY0 M2 M6 SB
9-14 ADSP-219x Instruction Set Reference
Table 9-5. Core registers (Contd)
RGP/Address Register Groups (RGP)
Address 00 (REG0) 01 (REG1) 10 (REG2) 11 (REG3)
0111 MY1 M3 M7 PX
1000 MR2 L0 L4 DMPG1
1001 SR2 L1 L5 DMPG2
1010 AR L2 L6 IOPG
1011 SI L3 L7 IJPG
1100 MR1 IMASK Reserved Reserved
1101 SR1 IRPTL Reserved Reserved
1110 MR0 ICNTL CNTR Reserved
1111 SR0 STACKA LPSTACKA STACKP
SF Function Codes
Table 9-6 list the shift function (SF) codes used by these instruction types:
• “Type 12: Shift | Dreg «···» DM/PM” on page 9-35
• “Type 14: Shift | Dreg1 «··· Dreg2” on page 9-36
• “Type 15: Shift Data8” on page 9-37
—shift functions (codes 00000111) only
• “Type 16: Shift Reg0” on page 9-38
ADSP-219x Instruction Set Reference 9-15
Instruction Opcodes
Table 9-6. SF codes
Code Function
0000 LSHIFT (HI)
0001 LSHIFT (HI, OR)
0010 LSHIFT (LO)
0011 LSHIFT (LO, OR)
0100 ASHIFT (HI)
0101 ASHIFT (HI, OR)
0110 ASHIFT (LO)
0111 ASHIFT (LO, OR)
1000 NORM (HI)
1001 NORM (HI, OR)
1010 NORM (LO)
1011 NORM (LO, OR)
1100 EXP (HI)
1101 EXP (HIX)
1110 EXP (LO)
1111 Derive Block Exponent
9-16 ADSP-219x Instruction Set Reference
I and M Codes
Table 9-7 on page 9-17 lists the DAG index and modify register codes
used by the following instruction types. The G bit (DAG1/DAG2) determines
which group of I (index) and M (modify) registers.
• “Type 4: Compute | Dreg «···» DM/PM” on page 9-23.
• “Type 12: Shift | Dreg «···» DM/PM” on page 9-35
• “Type 19: Indirect Jump/Call” on page 9-41
• “Type 21: Modify DagI” on page 9-43
• “Type 21a: Modify DagI” on page 9-44
• “Type 22: DM/PM «··· Data16” on page 9-45
• “Type 29: Dreg «···» DM” on page 9-51
• “Type 32: Any Reg «···» PM/DM” on page 9-54
Table 9-7. I and M codes
DAG1 (G=0) DAG2 (G=1)
Code I M I M
00 I0 M0 I4 M4
01 I1 M1 I5 M5
10 I2 M2 I6 M6
11 I3 M3 I7 M7
ADSP-219x Instruction Set Reference 9-17
Instruction Opcodes
DMI, DMM, PMI, and PMM Codes
Table 9-8 lists the DAG index and modify register codes used by “Type 1:
Compute | DregX«···DM | DregY«···PM” on page 9-21.
Table 9-8. DMI, DMM, PMI, PMM codes
Code DMI DMM PMI PMM
00 I0 M0 I4 M4
01 I1 M1 I5 M5
10 I2 M2 I6 M6
11 I3 M3 I7 M7
IREG/MREG Codes
Table 9-9 lists the Ireg and Mreg codes used by “Type 3: Dreg/Ireg/Mreg
«···» DM/PM” on page 9-22 to specify a DAG index or modify register.
Table 9-9. Ireg, Mreg codes
Code Register Code Register
0000 I0 1000 M0
0001 I1 1001 M1
0010 I2 1010 M2
0011 I3 1011 M3
0100 I4 1100 M4
0101 I5 1101 M5
9-18 ADSP-219x Instruction Set Reference
Table 9-9. Ireg, Mreg codes (Contd)
Code Register Code Register
0110 I6 1110 M6
0111 I7 1111 M7
XOP and YOP Codes
Table 9-10 on page 9-19 lists the XOP and YOP codes used by these
instructions:
• “Type 1: Compute | DregX«···DM | DregY«···PM” on page 9-21
• “Type 4: Compute | Dreg «···» DM/PM” on page 9-23
• “Type 8: Compute | Dreg1 «··· Dreg2” on page 9-26
• “Type 9: Compute” on page 9-27
• “Type 12: Shift | Dreg «···» DM/PM” on page 9-35
• “Type 23: Divide primitive, DIVQ” on page 9-47
• “Type 24: Divide primitive, DIVS” on page 9-48
Table 9-10. XOP/YOP codes
XOP YOP
Code ALU MAC Shift Code ALU MAC
000 AX0 MX0 SI 00 AY0 MY0
001 AX1 MX1 SR2 01 AY1 MY1
010 AR AR AR 10 AF SR1
ADSP-219x Instruction Set Reference 9-19
Instruction Opcodes
Table 9-10. XOP/YOP codes
XOP YOP
Code ALU MAC Shift Code ALU MAC
011 MR0 MR0 MR0 11 0 0
100 MR1 MR1 MR1
101 MR2 MR2 MR2
110 SR0 SR0 SR0
111 SR1 SR1 SR1
Opcode Definitions

37
testrom/gen_testrom.py Normal file
View File

@@ -0,0 +1,37 @@
import sys
import struct
import os
# Opcode constants
TYPE1_NOP = 0xC00000
TYPE6_AX0 = 0x400000
TYPE10_JUMP_ALWAYS = 0x18000F
TYPE30_NOP = 0x000000
def create_rom(filename, format=3):
"""
Creates a synthetic ADSP-219x ROM with known instruction patterns.
"""
os.makedirs(os.path.dirname(filename), exist_ok=True)
instructions = [
TYPE30_NOP, # 0x0000: NOP
TYPE6_AX0 | (0x1234 << 4), # 0x0001: AX0 = 0x1234
TYPE10_JUMP_ALWAYS | (0x0100 << 4), # 0x0002: JUMP 0x0100
# ... add more test patterns ...
]
with open(filename, "wb") as f:
for ins in instructions:
if format == 3:
# Big-endian 3-byte pack
f.write(struct.pack(">I", ins)[1:])
else:
# Big-endian 4-byte pad
f.write(struct.pack(">I", ins))
if __name__ == "__main__":
# Ensure full path to base_test.bin
base_dir = os.path.dirname(os.path.abspath(__file__))
create_rom(os.path.join(base_dir, "test_roms/base_test.bin"), 3)
create_rom(os.path.join(base_dir, "test_roms/padded_test.bin"), 4)
print("Test ROMs generated in test_roms/")

Binary file not shown.